Limits of body composition assessment by bioelectrical impedance analysis (BIA)
Authors/Creators
Description
Wasyluk Weronika, Wasyluk Martyna, Zwolak Agnieszka, Łuczyk Robert Jan. Limits of body composition assessment by bioelectrical impedance analysis (BIA). Journal of Education, Health and Sport. 2019;9(8):35-44. eISNN 2391-8306. DOI http://dx.doi.org/10.5281/zenodo.3359808
http://ojs.ukw.edu.pl/index.php/johs/article/view/7208
https://pbn.nauka.gov.pl/sedno-webapp/works/920495
The journal has had 5 points in Ministry of Science and Higher Education parametric evaluation. § 8. 2) and § 12. 1. 2) 22.02.2019.
© The Authors 2019;
This article is published with open access at Licensee Open Journal Systems of Kazimierz Wielki University in Bydgoszcz, Poland
Open Access. This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author (s) and source are credited. This is an open access article licensed under the terms of the Creative Commons Attribution Non commercial license Share alike.
(http://creativecommons.org/licenses/by-nc-sa/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited.
The authors declare that there is no conflict of interests regarding the publication of this paper.
Received: 05.07.2019. Revised: 25.07.2019. Accepted: 02.08.2019.
Limits of body composition assessment by bioelectrical impedance analysis (BIA)
Weronika Wasyluk, Martyna Wasyluk, Agnieszka Zwolak1, Robert Jan Łuczyk1
1Katedra Interny z Zakładem Pielęgniarstwa Internistycznego, Uniwersytet Medyczny w Lublinie
1Chair of Internal Medicine and Department of Internal Medicine in Nursing
Medical University of Lublin
Abstract
Bioelectrical impedance analysis (BIA) is a safe, non-invasive and repeatable method of body composition assessment, based on diversified electrical conduction through the aqueous and fat compartment of the body. The popularity and availability of the BIA study has increased in recent years. The aim of the work is to discuss its limitations, which can be divided into factors affecting the measurement of parameters and contraindications for measurements. The first group includes body structure, obesity and malnutrition, body temperature, intake of fluids and foods, changes in hydration and water and electrolyte balance, physical activity, long-term staying in a supine position, examination procedure and method of placing measuring electrodes. Contraindications include implanted cardiac devices (cardiac pacemaker, implantable cardioverter-defibrillator, resynchronization therapy), metal implants and pregnancy. There is no unambiguous confirmation of the validity of the mentioned contraindications in literature. Knowing the limitations of BIA is important because parts of potential errors can be avoided by properly preparing for the examination and following appropriate procedures during the measurements.
Keywords: bioelectrical impedance analysis; BIA