Journal article Open Access

A VALIDATED CHIRAL HPLC METHOD FOR THE ENANTIOMERIC PURITY OF ANAGLIPTIN

K. Durga Malleswar1, B. Venugopala Rao*1, S.Shylaja2.

An isocratic chiral phase high-performance liquid chromatographic method has been developed and validated to quantitation the (R)-isomer in Anagliptin. Separation was achieved in a Lux Cellulose-3 (250×4.6mm, 5μm) column. The ratio of hexane, ethanol and diethyl amine in the mobile phase were optimized to obtain the best separation. UV detection was performed at 254 nm. The described method is linear over a range of LOQ – 1.4 μg/mL of (R)-isomer. The mean recovery of (R)-isomer was found to be in the range of 100–102%. The method is simple, accurate, selective and precise. The method can be used in the quality control of bulk manufacturing.

Files (670.4 kB)
Name Size
190609.pdf
md5:b44bfb3ca246b24a12ddb50dfbc96440
670.4 kB Download
78
45
views
downloads
All versions This version
Views 7878
Downloads 4545
Data volume 30.2 MB30.2 MB
Unique views 7474
Unique downloads 4040

Share

Cite as