Published January 25, 2017 | Version v1

ELECTROCHEMICAL STUDIES OF PARACETAMOL ON POLYANILINE-SILVER NANOSTRUCTURAL THIN FILMS MODIFIED GLASSY CARBON ELECTRODE

  • 1. Department of Chemistry, Karpagam University, Karpagam Academy of Higher Education, Coimbatore, Tamilnadu
  • 2. Department of Chemistry, Sri Ranganathar Institute of Engineering and Technology, Coimbatore, Tamilnadu
  • 3. Department of Chemistry, Arignar Anna Government Arts College, Cheyyar, Tiruvannamalai, Tamilnadu

Description

Analysis of biomolecule of paracetamol through stripping voltammetric determination procedure on polyaniline-silver thin films modified glassy carbon electrode. The effect of pH was studied at different pH media such as 1.0 to pH 13.0.  The voltammetric investigation of paracetamol was carried out from −0.2 V to 1.2 V versus Ag/AgCl using modified glassy carbon (GC) as working electrode. The electroanalytical determination parameters are highly dependent on their configuration and on the dimensions of the working carbon electrode. The cyclic voltammogram exhibited one oxidation and one reduction peak. Peak current dependence on the scan rate is studied by varying the scan rate from 25 to 500 mv/s at concentration 300 ppm. The best limit of detection obtained for paracetamol was 10 ppb and the linear range from 100 to 600 ppb on GCE configuration. The biosensors were successfully applied for the detection of paracetamol in several drug formulations.

Files

55.pdf

Files (426.6 kB)

Name Size
md5:0a191a0c45561b6d251dcb1ede6e535b
426.6 kB Preview Download

Additional details

References

  • 1. Uslu B, Ozkan S A, 2007. Electroanalytical application of carbon based electrodes to the pharmaceuticals. Analytical Letters, 40(5): 817-853 2. Kim J H, Nam K W, Ma S B, Kim K B, 2006. Fabrication and electrochemical properties of carbon nanotube film electrodes. Carbon, 44(10): 1963-1968 3. Cruz-Vera M, Lucena R, Cárdenas S, Valcarcel M, 2008. Combined use of carbon nanotubes and ionic liquid to improve the determination of antidepressants in urine samples by liquid chromatography. Analytical and Bioanalytical Chemistry, 391(4): 1139-1145 4. Ahammad A J S, Lee J J, Rahman M A, 2009. Electrochemical sensors based on carbon nanotubes. Sensors, 9(4): 2289-2319. 5. Hirlekar R, Yamagar M, Garse H, Vij M, Kadam V, 2009. Carbon nanotubes and its applications: a review. Asian Journal of Pharmaceutical and Clinical Research, 2(4): 17-27 6. Shahrokhiana S, Ghalkhani M, Adeli M, Amini M K, 2009. Multi-walled carbon nanotubes with immobilised cobalt nanoparticle for modification of glassy carbon electrode: Application to sensitive voltammetric determination of thioridazine. Biosensors and Bioelectronics, 24(11): 3235-3241 7. Murugananthan M, Yoshihara S, Rakumab T, Shirakashi T, 2008. Mineralization of bisphenol A (BPA) by anodic oxidation with boron-doped diamond (BDD) electrode. Journal of Hazardous Materials, 154(1-3): 213-220 8. Koparal A S, Yavuz Y, Gurel C, Oğutveren U B, 2007. Electrochemical degradation and toxicity reduction of C. I. Basic Red 29 solution and textile wastewater by using diamond anode. Journal of Hazardous Materials, 145(1-2): 100-108 9. Bensalah N, Alfaro M A Q, Martínez-Huitle C A, 2009. Electrochemical treatment of synthetic wastewaters containing Alphazurine A dye. Chemical Engineering Journal, 149(1-3): 348-352 10. Rasu Ramachandran1, Shen-Ming Chen, George peter Gnana kumar, Pandi Gajendran Natrajan Biruntha Devi, Int. J. Electrochem. Sci., 10 (2015) 8607 – 8629 11. Mansour Ghaffari-Moghaddam, Hassan Eslahi, Arabian Journal of Chemistry (2014) 7, 846–855