Published January 22, 2025 | Version v1

Bar Signal Data Derived from a Compression-to-Tension Stress Conversion Structure in an SHPB Test

  • 1. Mechanical Engineering, Kyunghee University College of Engineering
  • 2. ROR icon Gangneung–Wonju National University
  • 3. Materials Engineering,Gangneung-Wonju National University College of Engineering
  • 4. Kyunghee University College of Engineering
  • 5. ROR icon Agency for Defense Development

Description

A specimen designed to convert compressive stress into tensile stress during the split Hopkinson pressure bar (SHPB) test is employed for the inverse calibration of a constitutive model for steel with a flow stress exceeding approximately 1,600 MPa. This calibration is accomplished by tracking the bar signals through repeated simulations. The maximum strain rate, strain, and temperature were approximately 6,500 /s, 0.53, and 550 K, respectively. These values significantly surpassed those obtained from a standard SHPB test, as predicted by an Excel template referenced elsewhere. The advantages of the proposed calibration method are discussed in comparison to the conventional approach.

Files

Files (8.7 MB)

Name Size
md5:ef80ba7daf7e8e999a70d836451b5aed
1.2 MB Download
md5:e5655cf3b3dd0d8d5c939ddfe6adea88
3.4 MB Download
md5:0d2874b096151c56461b18966baf24d2
4.0 MB Download