Published October 16, 2024 | Version v2

ML-EM based Dual tracer PET image reconstruction with inclusion of prompt gamma attenuation

  • 1. Forschungszentrum Jülich
  • 1. Forschungszentrum Jülich

Description

Conventionally, if two metabolic processes are of interest for image analysis, two separate, sequential PET scans are performed. However, sequential PET scans cannot simultaneously display the metabolic targets. The concurrent study of two simultaneous PET scans could provide new insights into the causes of diseases, such as, neurological disorders.
In this work, we propose a reconstruction algorithm for the simultaneous injection of a β+-emitter emitting only annihilation photons and a β+-γ-emitter emitting annihilation photons and an additional prompt γ-photon. As in previous works, the γ-photon is used to identify events originating from the β+-γ-emitter. However, due to e.g. attenuation and down-scatter, the γ-photon is often not detected and not all events can correctly be associated with the β+-γ-emitter as they are detected as double coincidences. In contrast to previous works, we estimate this number of double coincidences with origin in the β+-γ, emitter including the attenuation of the prompt γ, and incorporate this estimation in the forward-projection of the ML-EM algorithm.
For evaluation, we simulate different scenarios with varying objects and attenuation maps. The nuclide 18F serves as β+-emitter, while 44Sc functions as β+-γ emitter. The performance of the algorithm is assessed by calculating the residual error of the β+-γ-emitter in the reconstructed β+-emitter image. Additionally, the intensity values in the simulated cylinders of the ground truth (GT) and the reconstructed images are
compared. The remaining activity in the β+-emitter image varied from 0.4% to 4.8%.
The absolute percentage difference between GT and reconstructed intensity for the pure β+ emitter images was found to be between 2.7 and 12.3% for all simulated cases. The absolute percentage difference between the GT and the reconstructed intensity for the β+-γ emitter images ranged from 1.9 to 13.3% for all simulated cases. These results demonstrate that our approach can reconstruct two separate images with high quantitation accuracy.

Files

scen1beta.zip

Files (4.2 GB)

Name Size
md5:6d04ca14ce87606bcf153fc36d626cc2
1.4 GB Download
md5:2892d17c41fc9441804b410a89a6a7d5
11.0 MB Preview Download
md5:7b8af25bf6dea57d3cb62ff3dcb2917d
18.5 MB Preview Download
md5:149f731afc7b9af5fcac06dfaeafea15
1.5 GB Download
md5:75985dc9069b0e7c6fae3ef1d99f96fe
93.4 MB Preview Download
md5:a262b94b673ee87569c11a214e2bb1ee
85.5 MB Preview Download
md5:45cfe8946e7cdf7924f2cbae8d43b5d0
1.1 GB Preview Download
md5:296e94a41a6077bf6e80bfa7fbc4deea
3.9 MB Preview Download

Additional details

Funding

European Union
Marie- Curie Sklodowska Fellowship HORIZON-MSCA-2021- PF-01, grant 101068572

References

  • Andreyev, A and A Celler (2011). "Dual-isotope PET using positron-gamma emitters". In: Physics in Medicine & Biology 56.14, p. 453
  • Andreyev, Andriy, Arkadiusz Sitek, and Anna Celler (2014). "EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters". In: Medical physics 41.2, p. 022501.
  • Black, Noel F, Scott McJames, and Dan J Kadrmas (2009). "Rapid Multi-Tracer PET Tumor Imaging With F-FDG and Secondary Shorter-Lived Tracers". In: IEEE transactions on nuclear science 56.5, pp. 2750–2758.
  • Ch´etelat, Ga¨el et al. (2020). "Amyloid-PET and 18F-FDG-PET in the diagnostic investigation of Alzheimer's disease and other dementias". In: The Lancet Neurology 19.11, pp. 951–962.
  • Conti, Maurizio and Lars Eriksson (2016). "Physics of pure and non-pure positron emitters for PET: a review and a discussion". In: EJNMMI physics 3, pp. 1–17.
  • Dehdashti, Farrokh et al. (2003). "In vivo assessment of tumor hypoxia in lung cancer with 60 Cu-ATSM". In: European journal of nuclear medicine and molecular imaging 30, pp. 844–850.
  • Erba, Paola A et al. (2013). "FDG-PET in cardiac infections". In: Seminars in nuclear medicine. Vol. 43. Elsevier, pp. 377–39
  • Fang, Jingwan, Fuzhen Zeng, and Huafeng Liu (2024). "Signal separation of simultaneous dual-tracer PET imaging based on global spatial information and channel attention". In: EJNMMI physics 11.1, p. 47.
  • Fukuchi, Tomonori et al. (2021). "Image reconstruction method for dual-isotope positron emission tomography". In: Journal of Instrumentation 16.01, P01035
  • Gao, Fei et al. (2009). "Dynamic dual-tracer PET reconstruction". In: Information Processing in Medical Imaging: 21st International Conference, IPMI 2009, Williamsburg, VA, USA, July 5-10, 2009. Proceedings 21. Springer, pp. 38–49.
  • Graves, Stephen A et al. (2015). "Novel preparation methods of 52Mn for immunoPET imaging". In: Bioconjugate chemistry 26.10, pp. 2118–2124.
  • Hernandez, Reinier et al. (2014). "44Sc: an attractive isotope for peptide-based PET imaging". In: Molecular pharmaceutics 11.8, pp. 2954–2961
  • Kadrmas, Dan J, Thomas C Rust, and John M Hoffman (2013). "Single-scan dual-tracer FLT+ FDG PET tumor characterization". In: Physics in Medicine & Biology 58.3, p. 429.
  • Lerche, CW et al. (2023). "First Performance Results of a UHF-MRI Compatible BrainPET Insert for Neuroscience". In: 2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD). IEEE, pp. 1–2.
  • Meikle, Steven R et al. (2021). "Quantitative PET in the 2020s: a roadmap". In: Physics in medicine & biology 66.6, 06RM01.
  • Michel, C et al. (1998). "Preserving Poisson characteristics of PET data with weighted OSEM reconstruction". In: 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No. 98CH36255). Vol. 2. IEEE, pp. 1323–132
  • Myers, William G (1973). "Radiopotassium-38 for in vivo studies of dynamic processes". In: Journal of Nuclear Medicine 14.6, pp. 359–360.
  • Niek¨amper, D et al. (2023). "Precise and accurate coincidence processing for the BrainPET-7T with triple coincidences and randoms". In: 2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD). IEEE, pp. 1–1.
  • Pratt, Edwin C et al. (2023). "Simultaneous quantitative imaging of two PET radiotracers via the detection of positron–electron annihilation and prompt gamma emissions". In: Nature Biomedical Engineering 7.8, pp. 1028–1039.
  • Rust, TC et al. (2006). "Rapid dual-injection single-scan 13N-ammonia PET for quantification of rest and stress myocardial blood flows". In: Physics in Medicine & Biology 51.20, p. 534
  • Sala¨un, Pierre-Yves et al. (2020). "Good clinical practice recommendations for the use of PET/CT in oncology". In: European Journal of Nuclear Medicine and Molecular Imaging 47, pp. 28–50
  • Scheins, J¨urgen J, Fritz Boschen, and Hans Herzog (2006). "Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction". In: IEEE Transactions on Medical Imaging 25.10, pp. 1363–1369.
  • Schramm, Georg and Martin Holler (2022). "Fast and memory-efficient reconstruction of sparse Poisson data in listmode with non-smooth priors with application to timeof- flight PET". In: Physics in Medicine & Biology 67.15, p. 155020.
  • Sitek, Arkadiusz, Andriy Andreyev, and Anna Celler (2011). "Reconstruction of dual isotope PET using expectation maximization (EM) algorithm". In: 2011 IEEE Nuclear Science Symposium Conference Record. IEEE, pp. 4323–4326.
  • Topping, Geoffrey J et al. (2013). "Manganese-52 positron emission tomography tracer characterization and initial results in phantoms and in vivo". In: Medical Physics 40.4, p. 042502.
  • Umbricht, Christoph A et al. (2017). "44 Sc-PSMA-617 for radiotheragnostics in tandem with 177 Lu-PSMA-617—preclinical investigations in comparison with 68 Ga- PSMA-11 and 68 Ga-PSMA-617". In: EJNMMI research 7, pp. 1–10.
  • Zeng, Fuzhen et al. (2023). "Direct reconstruction for simultaneous dual-tracer PET imaging based on multi-task learning". In: EJNMMI research 13.1, p. 7.