Published July 20, 2012 | Version 3597

Study on the Particle Removal Efficiency of Multi Inner Stage Cyclone by CFD Simulation

Description

A new multi inner stage (MIS) cyclone was designed to remove the acidic gas and fine particles produced from electronic industry. To characterize gas flow in MIS cyclone, pressure and velocity distribution were calculated by means of CFD program. Also, the flow locus of fine particles and particle removal efficiency were analyzed by Lagrangian method. When outlet pressure condition was –100mmAq, the efficiency was the best in this study.

Files

3597.pdf

Files (685.5 kB)

Name Size
md5:26be9f65f63842a47aa22100b8094f6d