Published August 6, 2024
| Version v1
Dataset
Open
100 rotation datasets with 50 kGy-dose 360-deg collected from thermolysin
Authors/Creators
Description
Experimental conditions
| Beamline | SPring-8 BL32XU |
| Beam size | 10(h) x 15(v) µm^2 |
| Dose | 50 kGy / datasett |
| # of datasets | 100 |
| oscillation width | 0.1 º |
| oscillation range (each dataset) | 0-360º |
| Wavelength | 1 Å |
| Detector | EIGER X 9M (Dectris) |
| Exposure time | 0.02 sec/frame |
File contents
all.tar includes 100 x tgz files.
ex)
slice001.tgz -> 50 kGy 360 deg dataset 1st / 100
slice002.tgz -> 50 kGy 360 deg dataset 2nd / 100
slice003.tgz -> 50 kGy 360 deg dataset 3rd / 100
...
...
slice100.tgz -> 50 kGy 360 deg dataset 100th / 100
Note
- All 100 datasets were collected from 1 irradiation point on thermolysin crystal.
- All datasets were collected with identical oscillation range.
- Dose was accumulated to the irradiated volume.
- The total dose after 100 datasets roughly corresponded to 10 MGy.