Published October 3, 2016 | Version v1

Minimal Load Shedding Using the Swing Equation

  • 1. KIOS Center of Excellence, University of Cyprus

Description

Load shedding constitutes the very last resort for preventing total blackouts and cascading events. Conventional load shedding schemes, which are massively applied in industrial practice, adopt a step-wise approach that usually causes overshedding or fails to prevent frequency decay above the allowable limits. Recently proposed schemes based on real time intelligent control and neural networks achieve the control objective, but fail to minimize the amount of load to be shed due to the delay incurred in consecutive control decisions. This letter proposes a new load shedding scheme, decoupled from the conventional scheme. This scheme, based on the equivalent swing equation of the system, determines the minimal amount of load that should be shed immediately (in a single step) after the load event/disturbance occurs, in order to guarantee system stability.

Files

Minimal Load Shedding Using the Swing Equation.pdf

Files (260.2 kB)

Name Size
md5:b76e12e75813b19c313ba816a5284e6e
260.2 kB Preview Download

Additional details

Funding

European Commission
KIOS CoE - KIOS Research and Innovation Centre of Excellence 739551