Published August 5, 2016
| Version 10005565
Journal article
Open
Numerical Simulations of Fire in Typical Air Conditioned Railway Coach
Authors/Creators
Description
Railways in India remain primary mode of transport
having one of the largest networks in the world and catering to
billions of transits yearly. Catastrophic economic damage and loss
to life is encountered over the past few decades due to fire to
locomotives. Study of fire dynamics and fire propagation plays an
important role in evacuation planning and reducing losses. Simulation
based study of propagation of fire and soot inside an air conditioned
coach of Indian locomotive is done in this paper. Finite difference
based solver, Fire Dynamic Simulator (FDS) version 6 has been
used for analysis. A single air conditioned 3 tier coupe closed to
ambient surroundings by glass windows having occupancy for 8
people is the basic unit of the domain. A system of three such
coupes combined is taken to be fundamental unit for the entire
study to resemble effect to an entire coach. Analysis of flame and
soot contours and concentrations is done corresponding to variations
in heat release rate per unit volume (HRRPUA) of fire source,
variations in conditioned air velocity being circulated inside coupes
by vents and an alternate fire initiation and propagation mechanism
via ducts. Quantitative results of fractional area in top and front
view of the three coupes under fire and smoke are obtained using
MATLAB (IMT). Present simulations and its findings will be useful
for organizations like Commission of Railway Safety and others in
designing and implementing safety and evacuation measures.
having one of the largest networks in the world and catering to
billions of transits yearly. Catastrophic economic damage and loss
to life is encountered over the past few decades due to fire to
locomotives. Study of fire dynamics and fire propagation plays an
important role in evacuation planning and reducing losses. Simulation
based study of propagation of fire and soot inside an air conditioned
coach of Indian locomotive is done in this paper. Finite difference
based solver, Fire Dynamic Simulator (FDS) version 6 has been
used for analysis. A single air conditioned 3 tier coupe closed to
ambient surroundings by glass windows having occupancy for 8
people is the basic unit of the domain. A system of three such
coupes combined is taken to be fundamental unit for the entire
study to resemble effect to an entire coach. Analysis of flame and
soot contours and concentrations is done corresponding to variations
in heat release rate per unit volume (HRRPUA) of fire source,
variations in conditioned air velocity being circulated inside coupes
by vents and an alternate fire initiation and propagation mechanism
via ducts. Quantitative results of fractional area in top and front
view of the three coupes under fire and smoke are obtained using
MATLAB (IMT). Present simulations and its findings will be useful
for organizations like Commission of Railway Safety and others in
designing and implementing safety and evacuation measures.
Files
10005565.pdf
Additional details
References
- "26 die in sleep as fire breaks out on train from bangalore," The Indian Express, 2013-12-29.
- "Two howrah-dehradun express coaches catch fire, 7 dead," India Today, 2011-11-22.
- "Two ac coaches of gt express from chennai catch fire," Hindustan Times, 2012-11-30.
- N. Markatos, M. Malin, and G. Cox, "Mathematical modelling of buoyancy-induced smoke flow in enclosures," International Journal of Heat and Mass Transfer, vol. 25, no. 1, pp. 63–75, 1982.
- S.-J. MO, Z.-R. Li, D. Liang, J.-X. Li, and N.-J. Zhou, "Analysis of smoke hazard in train compartment fire accidents base on fds," Procedia Engineering, vol. 52, pp. 284–289, 2013.
- W.-K. Chow, K. Lam, N. Fong, S. Li, and Y. Gao, "Numerical simulations for a typical train fire in china," Modelling and Simulation in Engineering, vol. 2011, p. 4, 2011.
- N. White, V. Dowling, and J. Barnett, "Full-scale fire experiment on a typical passenger train," Fire Safety Science, vol. 8, pp. 1157–1168, 2005.
- H. Ingason and A. L¨onnermark, "Heat release rates from heavy goods vehicle trailer fires in tunnels," Fire Safety Journal, vol. 40, no. 7, pp. 646–668, 2005.
- R. D. Peacock, P. A. Reneke, W. W. Jones, R. W. Bukowski, and V. Babrauskas, "Concepts for fire protection of passenger rail transportation vehicles: past, present, and future," Fire and Materials, vol. 19, no. 2, pp. 71–87, 1995. [10] A. Haack, "Fire protection in traffic tunnels: general aspects and results of the eureka project," Tunnelling and underground space technology, vol. 13, no. 4, pp. 377–381, 1998. [11] A. Enbaya, T. Asim, R. Mishra, and R. B. Rao, "Fire safety analysis of a railway compartment using computational fluid dynamics," International Journal of COMADEM, 2015. [12] S. Vatsal and D. Arup Kumar, "Building fire safety: Numerical simulation and evacuation planning," in International Conference of the International Building Performance Simulation Association, Hyderabad, India, December 7-9, 2015, vol. 14. IBPSA, 2016, pp. 897–904. [13] A. Yuen, G. Yeoh, R. Alexander, and M. Cook, "Fire scene reconstruction of a furnished compartment room in a house fire," Case Studies in Fire Safety, vol. 1, pp. 29–35, 2014. [14] H.-T. Chen and S.-K. Lee, "Estimation of heat-transfer characteristics on the hot surface of glass pane with down-flowing water film," Building and environment, vol. 45, no. 10, pp. 2089–2099, 2010. [15] A complete guide to Indian railway air conditioning. Indian Railways Institute of Electrical Engineering Nasik. [16] K. McGrattan, S. Hostikka, J. Floyd, H. Baum, R. Rehm, W. Mell, and R. McDermott, "Fire dynamics simulator (version 5), technical reference guide," NIST special publication, vol. 1018, no. 5, 2004. [17] K. B. McGrattan and G. P. Forney, Fire Dynamics Simulator: User's Manual. US Department of Commerce, Technology Administration, National Institute of Standards and Technology, 2000.