Results of inter-laboratory testing on COSC-1 cores and reference samples (density, porosity, thermal properties)

  • 1. Ruhr-Universität Bochum

Description

The data files contain the results of comparative measurements of thermal properties of four widely used rock references and nine core samples originating from the ICDP COSC-1 borehole, using a steady-state and a transient divided-bar device, a transient plane source device, a modified Angstrom device, as well as two optical thermal conductivity scanners. In addition, the Dewar method provided benchmark values for specific heat capacity. 

participating institutions and methods (acronyms used in file headers)

Chalmers University (CU) transient plane source (TPS)
Geological Survey of Sweden (SGU) optical scanning (TCS)
Ruhr-Universit ̈at Bochum (RUB) Dewar method, modified Angstrom (mAng), optical scanning (TCS)
Aarhus University (AU) transient divided bar (TDB)
University College Dublin (UCD) divided bar (DB)