Published September 4, 2015
| Version 10002536
Journal article
Open
Thermal Behavior of a Ventilated Façade Using Perforated Ceramic Bricks
Authors/Creators
Description
The ventilated façade has great advantages when
compared to traditional façades as it reduces the air conditioning
thermal loads due to the stack effect induced by solar radiation in the
air chamber. Optimizing energy consumption by using a ventilated
façade can be used not only in newly built buildings but also it can be
implemented in existing buildings, opening the field of
implementation to energy building retrofitting works. In this sense, the following three prototypes of façade where
designed, built and further analyzed in this research: non-ventilated
façade (NVF); slightly ventilated façade (SLVF) and strongly
ventilated façade (STVF). The construction characteristics of the
three facades are based on the Spanish regulation of building
construction "Technical Building Code". The façades have been
monitored by type-k thermocouples in a representative day of the
summer season in Madrid (Spain). Moreover, an analysis of variance
(ANOVA) with repeated measures, studying the thermal lag in the
ventilated and no-ventilated façades has been designed. Results show that STVF façade presents higher levels of thermal
inertia as the thermal lag reduces up to 17% (daily mean) compared
to the non-ventilated façade. In addition, the statistical analysis
proves that an increase of the ventilation holes size in STVF façades
can improve the thermal lag significantly (p >0.05) when compared
to the SLVF façade.
Files
10002536.pdf
Additional details
References
- Institute for Diversification and Energy Savings (IDAE). Plan for Energy Saving and Efficiency 2011-2020. 2nd National Action Plan for Energy Efficiency in Spain. Available in: http://www.idae.es (Query: February, 2015).
- Directive 2002/91/CE of the European Parliament and of the Council of 16 December 2002 on the energy performance of buildings.
- Directive 20010/91/CE of the European Parliament and of the Council of 19 May 2002 on the energy performance of buildings (recast)
- Real Decreto 314/2006, of 17 March 2006 amending the Technical Building Code is approved. Available in: http://www.codigotecnico.org (Query: March 10, 2011).
- Real Decreto 47/2007, of January 19, amending the Basic Procedure for certification of energy efficiency of new buildings is approved.
- E. Giancola A.; C. Sanjuan A.; E. Blanco B.; M. R. Heras. Experimental assessment and modelling of the performance of an open joint¸ ventilated façade during actual operating conditions in Mediterranean climate. Energy and Buildings, 2012, Vol.54, 363-375
- Patania, F.; Gagliano, A.; Nocera, F.; Ferlito, A.; Gasely, A.. "Thermofluid- dynamic analysis of ventilated facades". Energy and Buildings, 2010, Vol.42, Issue 7, 148-155.
- Suareza, C.; Joubert, P.; Molina, J. L.; Sánchez, F. J. "Heat transfer and mass flow correlations for ventilated facades". Energy and Buildings, 2011, Vol.43, 3696-3703.
- García de María, J. M. Baïri, A., Costa V. A. F. "Empirical correlations at high Ra for steady-state free convection in 2D air filled parallelogrammic enclosures with discrete heat sources". International Journal of Heat and Mass Transfer, Vol. 53, Issues 19-20, September 2010, Pages 3831-3838 [10] Silvestre L., García de María, J. M., Camarasa M., Viñas C. "Thermal study of glass façades". VII National Congress of Engineering Thermodynamic. Bilbao. June 2011 [11] Kinnear, P. R. and C. D. Gray, SPSS 15 Made Simple, ed. P.P. Ltd. 2007, Brighton & Hove and New York: Taylor & Francis Group.