Published January 1, 2015 | Version 10000312

Design and Implementation of DC-DC Converter with Inc-Cond Algorithm

Description

The most important component affecting the
efficiency of photovoltaic power systems are solar panels. In other
words, efficiency of these systems are significantly affected due to
the being low efficiency of solar panel. Thus, solar panels should be
operated under maximum power point conditions through a power
converter. In this study, design of boost converter has been carried
out with maximum power point tracking (MPPT) algorithm which is
incremental conductance (Inc-Cond). By using this algorithm,
importance of power converter in MPPT hardware design, impacts of
MPPT operation have been shown. It is worth noting that initial
operation point is the main criteria for determining the MPPT
performance. In addition, it is shown that if value of load resistance is
lower than critical value, failure operation is realized. For these
analyzes, direct duty control is used for simplifying the control.

Files

10000312.pdf

Files (315.1 kB)

Name Size
md5:ab6eca1301e38158530426b5fcf6f5ac
315.1 kB Preview Download

Additional details

References

  • K. B. Varınca, "Türkiye'de günes enerjisi potansiyeli ve bu potansiyelin kullanım derecesi, yöntemi ve yaygınlığı üzerine bir arastırma," in I. Ulusal Günes ve Hidrojen Enerjisi Kongresi, Eskisehir, 2006, pp. 270- 275.
  • Energy&Sustainable Environmental Technologies, Repuclic of Turkey Prime Ministry Investment Support and Promotion Agency, http://www.invest.gov.tr (Available: 22.07.2014).
  • T. Esram, "Comparison of photovoltaic array maximum power point tracking techniques," IEEE Trans. on Energy Conversion, vol. 22, pp. 439-449, 2007.
  • T. Noguchi, S. Togashi, R. Nakamoto, "Short-current pulse-based maximum power point tracking method for multiple photovoltaic and converter module system," IEEE Trans. on Industrial Electronics, vol. 49, pp. 217-223, 2002.
  • I. Houssamo, F. Locment, M. Sechilariu, "Maximum power point tracking for photovoltaic system: Development and experimental comparison of two algorithms," Renewable Energy, vol. 35, pp. 2381- 2387, 2010.
  • C. H. Lin, C. H. Huang, Y.C. Du, J. L. Chen, "Maximum photovoltaic power tracking for the PV array using the fractional-order incremental conductance method," Applied Energy, vol. 88, pp. 4840-4847, 2011.
  • A. Dolara, R. Faranda, "Energy comparison of seven MPPT techniques for PV system," Journal of Electromagnetic Analysis & Applications, vol. 3, pp. 152-162, 2009.
  • F. Duan, F. Liu, B. Liu, Y. Kang, "A variable step size INC MPPT method for PV systems," IEEE Trans. on Industrial Electronics, vol. 55, pp. 2622-2628, 2008.
  • A. R. Reisi, M. H. Moradi, S. Jamasb, "Classification and comparison of maximum power point tracking techniques for photovoltaic system: A review," Renewable and Sustainable Reviews, vol. 19, pp. 433-443, 2010. [10] H. S. Chung, K. K. Tse, S. Y. R. Hui, C. M. Mok, M. T. Ho, "A novel maximum power point tracking technique for solar panels using a sepic or cuk converter," IEEE Trans. on Power Electronics, vol. 18, pp. 717- 724, 2003. [11] M. E. Basoğlu, " Günes Enerjisi Sistemlerinde Kullanılan Maksimum Güç Noktası Đzleyicili Yükseltici DA-DA Dönüstürücü Analizi ve Gerçeklestirilmesi, Master Thesis, Institute of Science Kocaeli University, 2013.