Thyroids Dose Evaluation and Calculation of Backscatter Factors for Co-60 Irradiations
Authors/Creators
Description
The aim of the study is evaluation of absorbed doses for thyroids by using neck phantoms. For this purpose, it was arranged the irradiation set with different phantoms. Three different materials were used for phantom materials as, water, parafine and wood. The phantoms were three different dimensions for simulation of different ages and human race for each material. Co-60 gammao source was used for irradiation and the experimental procedure applied rigorously with narrow beam geometry. As the results of the experiments the relative radiation doses are evaluated for therapic applications for thyroids and backscattering factors were calculated and shown that water, parafine and wood can appropriate for phantom material with the converge values of backscattering factors.
Files
16713.pdf
Additional details
References
- R.F. Hill, S. Brown, C. Baldock, Radiation Measurements vol.43, 2008,pp.1258.
- D.Yasar, A.B.Tugrul, "A comparison of TLD measurementsto MIRD estimates of the dosetothetestesfrom Tc-99m in theliverandspleen", Radiation Measurements, Vol.37, 2003, pp. 113-118
- R. Shivaramu, L. Vijayakumar, N. Rajasekaran, Ramamurthy, Radiation Physics and Chemistry vol.62, 2001, pp. 371.
- M.Kurudirek,Waterequivalencestudyofsomephantomsbasedoneffectivep hoton energy,effectiveatomicnumbersandelectrondensitiesforclinical MV X-rayandCo-60 g-ray beams, Nuclear Instruments and Methods in Physics Research A 701 (2013) 268–272
- H. Saitoh, T. Tomaru, T. Fujisaki, S. Abe, A. Myojoyamaand K. Fukuda,A Study on Propertıes of Water Substıtute Solid Phantom Using EGS Code, Tenth EGS4 Users' Meeting, Japan, Proc. 2002-18, pp.55- 64.
- M.A. Hassan, M.H. Gaber, E. Esmat, H.I. Farag, H.M. Eıssa, Standard Water Phantom Backscatter Factors For Medium Energy X-Rays, Romanian J. Biophys., Vol. 14, Nos. 1–4, P. 69–79, 2004.
- S.C. Klevenhagen, Experimentally determined backscatter factors for Xrays generated at voltages between 16 and 140kV, Phys. Med. Biol.,1989, Vol.34, 1871–1882.
- A.B. Tuğrul, "A New Approach For Calculating The Geometry Factor For Flow Measurements With Radioactive Tracers", Kerntechnik,vol: 60, No: 5-6, pp: 265-266, (1995)
- D. Kısınma, Dosimetric Evaluation for Thyroids By Using Different Phantoms, ITU Energy Institute, MSc Thesis, (continued).