Characterization of ZrO2/PEG Composite Film as Immobilization Matrix for Glucose Oxidase

Description

A biosensor based on glucose oxidase (GOx) immobilized onto nanoparticles zirconium oxide with polyethylene nanocomposite for glucose monitoring has been designed. The CTAB/PEG/ZrO2/GOx nanocomposite was deposited onto screen printed carbon paste (SPCE) electrode via spin coating technique. The properties of CTAB/PEG/ZrO2/GOx were study using scanning electron microscopy (SEM). The SPE modified with the CTAB/PEG/ZrO2/GOx showed electrocatalytical response to the oxidation of glucose when ferrocene carboxaldehyde was used as an artificial redox mediator, which was studied by cyclic voltammetry (CV). Several parameters such as working potential, effect of pH and effect of ZrO2/PEG layers that governed the analytical performance of the biosensor, have been studied. The biosensor was applied to detect glucose with a linear range of 0.4 to 2.0 mmol L−1 with good repetability and reproducibility.

Files

16054.pdf

Files (970.7 kB)

Name Size
md5:2a30ec4f060fa5dfa43039b8d8a50b8b
970.7 kB Preview Download

Additional details

References

  • S. V. Dzyadevycha, A. P. Soldatkina, A. V. El'skayaa, C. Marteletb, N. Jaffrezic-Renaultb, Analytica Chimica Acta, 568, 248 (2006).
  • S.Singh, P.R. Solanki, M.K. Pandey, B.D. Malhotra. Analytica Chimica Acta. 568, 126 (2006).
  • S. Liu, Z. Dai, H. Chen, H. Ju, Biosensors and Bioelectronics, 19, 963 (2004).
  • M.Y. Chang, R.S. Juang, Int. J. Biological Macromolecules, 40, 224 (2007).
  • Y. Ma, G. Zhan, M. Ma, X. Wang, C. Li, Bioelectrochemistry, 84, 6 (2012).
  • K. Qiao, N. Hu, Bioelectrochemistry, 75, 71 (2009).
  • F. Wang, J. Yao, M. Russel, H. Chen, K. Chen, Y. Zhou, B. Ceccanti, G. Zaray, Martin M.F. Choi, Biosensors and Bioelectronics, 25, 2238 (2010).
  • Y. Yang, Z. Wang, M. Yang, J. Li, F. Zheng, G. Shen, R. Yu, Analytica Chimica Acta, 584, 268 (2007).
  • G. Sumana, M. Das, S. Srivastava, B.D. Malhotra, Thin Solid Films, 519, 1187 (2010). [10] R. Pratima Solanki, A. Kaushik, P.M. Chavhan, S.N. Maheshwari, B.D. Malhotra, Electrochemistry Communications, 11, 2272 (2009). [11] Y. Yang, H. Yang, M. Yang, Y. Liu, G. Shen, R. Yu, Analytica Chimica Acta, 525, 213 (2004). [12] G. Zhao, J.J. Feng, J.J. Xu, H.Y Chen, Electrochemistry Communications, 7, 724 (2005). [13] B. Liu, Y. Chao, D. Chen, J. Kong, J. Deng, Analytica Chimica Acta, 478, 59 (2003). [14] Y. Wang, X. Wang, B. Wu, Z. Zhao, F. Yin, S. Li, X. Qin, Q. Chen, Sensors and Actuators B: Chemical, 130, 809 (2008).