Published December 22, 2011
| Version 14103
Journal article
Open
Influence of Differences of Heat Insulation Methods on Thermal Comfort of Apartment Buildings
Authors/Creators
Description
The aim of this study is to analyze influence of
differences of heat insulation methods on indoor thermal environment and comfort of apartment buildings.
This study analyzes indoor thermal environment and comfort on units of apartment buildings using calculation software "THERB" and
compares three different kinds of heat insulation methods. Those are
outside insulation on outside walls, inside insulation on outside walls and interior insulation. In terms of indoor thermal environment, outside insulation is the best to stabilize room temperature. In winter, room temperature on
outside insulation after heating is higher than other and it is kept 3-5 degrees higher through all night. But the surface temperature with
outside insulation did not dramatically increase when heating was used, which was 3 to 5oC lower than the temperature with other
insulation. The PMV of interior insulation fall nearly range of comfort when the heating and cooling was use.
Files
14103.pdf
Additional details
References
- Guideline of Housing Energy Conservation Standard Third edition by Institute for Building Environment and Energy Conservation - July 2009.
- Expanded AMeDAS Weather Data from 1981 to 2000 by Architectural Institute of Japan - August 2005.
- Journal of Architectural Knowledge September edition.
- Hasegawa, K. and other three authors. Consideration of Adequate Insulation Levels for Apartment Houses in view of Indoor Thermal Environment. Journal of Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, 213-214.
- Architectural Environment Engineering by Morikita Publishing Co., Ltd - June 1996.