Published July 25, 2011 | Version 12446

HPL-TE Method for Determination of Coatings Relative Total Emissivity Sensitivity Analysis of the Influences of Method Parameters

Authors/Creators

Description

High power laser – total emissivity method (HPL-TE method) for determination of coatings relative total emissivity dependent on the temperature is introduced. Method principle, experimental and evaluation parts of the method are described. Computer model of HPL-TE method is employed to perform the sensitivity analysis of the effect of method parameters on the sample surface temperature in the positions where the surface temperature and radiation heat flux are measured.

Files

12446.pdf

Files (616.8 kB)

Name Size
md5:dc217ec0a89ea171ff4b46181f0b06f4
616.8 kB Preview Download

Additional details

References

  • M.F. Modest, Radiative Heat Transfer. San Diego, CA: Elsevier, 2003, 860 p.
  • J.F. Sacadura, "Measurement Techniques for Thermal Radiation Properties", in Proc. 9th International Heat Transfer Conference, 1990, pp. 207-222.
  • D.P. DeWitt, G.D. Nutter, Theory and Practice of Radiation Thermometry. New York: John Wiley, 1988, 1152 p.
  • B. Zhang, J. Redgrove, J. Clark, "A Transient Method for Total Emissivity Determination", International Journal of Thermophysics, vol. 25, no. 2, pp. 423-438, March 2004.