Published March 23, 2011
| Version 9543
Journal article
Open
Performance of Air Gap Membrane Distillation for Desalination of Ground Water and Seawater
Authors/Creators
Description
Membrane distillation (MD) is a rising technology for
seawater or brine desalination process. In this work, an air gap
membrane distillation (AGMD) performance was investigated for
aqueous NaCl solution along with natural ground water and seawater.
In order to enhance the performance of the AGMD process in
desalination, that is, to get more flux, it is necessary to study the
effect of operating parameters on the yield of distillate water. The
influence of operational parameters such as feed flow rate, feed
temperature, feed salt concentration, coolant temperature and air gap
thickness on the membrane distillation (MD) permeation flux have
been investigated for low and high salt solution. the natural
application of ground water and seawater over 90 h continuous
operation, scale deposits observed on the membrane surface and
reduction in flux represents 23% for ground water and 60% for
seawater, in 90 h. This reduction was eliminated (less than 14 %) by
acidification of feed water. Hence, promote the research attention in
apply of AGMD for the ground water as well as seawater
desalination over today-s conventional RO operation.
Files
9543.pdf
Additional details
References
- Semih Otles and Serkan Otles, "Desalination Techniques", Electron. J. Environ. Agric. Food Chem., 2004, pp. 963-969.
- L. Muthumariappan, "Energy conservation systems in reverse osmosis desalination plants", TWAD Technical Newsletter, January 2004.
- Bart Van der Bruggen, Carlo Vandecasteele, "Distillation vs. membrane filtration: overview of process evolutions in seawater desalination", Desalination, vol. 143, 2002, pp. 207-218.
- Sai R. Pinappu, "Composite membranes for membrane distillation desalination process", Final report, New Mexico State University, 2010.
- O. T. Komeslia, K. Teschnerb, W. Hegemannb, C. F. Gokcay, "Vacuum membrane applications in domestic wastewater reuse", Desalination, vol. 215, 2007, pp. 22-28.
- G.W. Meindersma, C.M. Guijt, A.B. de Haan, "Desalination and water recycling by air gap membrane distillation", Desalination, vol. 187, 2006, pp. 291-301.
- Jian-Mei Li, Zhi-Kang Xu, Zhen-Mei Liu, Wen-Feng Yuan, Hui Xiang, Shu-Yuan Wang, You-Yi Xu, "Micro porous polypropylene and polyethylene hollow fibre membranes: Part 3. Experimental studies on membrane distillation for desalination", Desalination, vol. 155, 2003, pp. 153-156.
- T. Mohammadi, M. Akbarabadi, "Separation of ethylene glycol solution by vacuum membrane distillation (VMD)", Desalination, vol. 181, 2005, pp. 35-41.
- Ying Xu, Bao-Ku Zhu, You-yi Xu, "Pilot test of vacuum membrane distillation for desalination on a ship", Desalination, vol. 189, 2006, pp. 165-169. [10] Zhao Jin, Da Ling Yang, Shou Hai Zhang, Xi Gao Jian, "Hydrophobic modification of poly (phthalazinone ether sulfone ketone) hollow fiber membrane for vacuum membrane distillation", J. Membr. Sci., vol. 310, 2008, pp. 20-27. [11] M. Khayet, M.P. Godino, J.I. Mengual, "Theoretical and experimental studies on desalination using the sweeping gas membrane distillation method", Desalination, vol. 157 2003, pp. 297-305. [12] J.I. Mengual, M. Khayet, M.P. Godino, "Heat and mass transfer in vacuum membrane distillation", Int. J. Heat and Mass Transfer, vol. 47, 2004, pp. 865-875. [13] H. Chang, C.L. Chang, C.D. Ho, C.C. Li, P.H. Wang, "Experimental and simulation of an air gap membrane distillation module with solar absorption function for desalination", Desalination and Water Treatment, vol. 25, 2011, pp. 251-258. [14] Manickam Matheswaran, Tae Ouk Kwon, Jae Woo Kim, Shik Moon, "Factors affecting flux and water separation performance in air gap membrane distillation", J. Ind. Eng. Chem., vol. 13, no. 6, 2007, pp. 965- 970. [15] Alaa Kullab, Andrew Martin, "Membrane distillation and applications for water purification in thermal cogeneration plants", Separation and Purification Technology, vol. 76, 2011, pp. 231-237.