Authors/Creators
Description
Eight steel reinforced concrete beams (SRC), were
fabricated and tested under earthquake type cyclic loading. The
effectiveness of intermediate stiffeners, such as mid-span stiffener and
plastic hinge zone stiffeners, in enhancing composite action and
ductility of SRC beams was investigated. The effectiveness of
strengthened beam-to-column (SBC) and weakened beam-to-column
(WBC) connections in enhancing beam ductility was also studied. It
was found that: (1) All the specimens possessed fairly high flexural
ductility and were found adequate for structures in high seismic zones.
(2) WBC connections induced stress concentration which caused extra
damage to concrete near the flange tapering zone. This extra damage
inhibited the flexural strength development and the ductility of the
specimens with WBC connections to some extent. (3) Specimens with
SBC connections demonstrated higher flexural strength and ductility
compared to specimens with WBC connections. (4) The intermediate
stiffeners, especially combination of plastic hinge zone stiffener and
mid span stiffeners, have an obvious effect in enhancing the ductility
of the beams with SBC connection.
Files
8259.pdf
Additional details
References
- Chen C.C. and Chen C.C., "Flexural behavior of steel encased composite beams," Journal of the Chinese Institute of Civil and Hydraulic Engineering, vol. 13, pp. 263-75, Feb. 2001.
- Plumier A., "Behavior of connections," Journal of Constructional. Steel Research, vol. 29, pp. 95-119, 1994
- Chen, S.J., Yeh, C.H. and Chu, J.M., "Ductile steel beam-to-column connection for seismic resistance," Journal of Structural Engineering.-ASCE, vol. 122, pp. 1292-9, Nov. 1996.
- Chen, S.J., Chu, J.M. and Chou, Z.L., ÔÇÿDynamic behavior of steel frames with beam flanges shaved around connection," Journal of Constructional Steel Research, vol. 42, pp. 49-70, Jan. 1997.
- Kim, T., Whittaker, A.S., Gilani, A.S.J., Bertero, V.V. and Takhirov, S.M., "Cover-plate and flange-plate steel moment-resisting connections," Journal of Structural Engineering.-ASCE, vol. 128, pp. 474-482, April 2002.
- Sumner, E.A. and Murray, T.M., "Behavior of extended end-plate moment connections subject to cyclic loading," Journal of structural engineering,-ASCE, vol. 128, pp. 501-8, April 2002.
- AISC., Specification for structural steel buildings. American Institute of Steel Construction, 2005, Chicago. IL.
- Chen C.C. and Cheng C.L., "Flexural analysis and design methods for SRC beam sections with complete composite action. Journal of the Chinese Institute of Civil and Hydraulic Engineering, vol. 31, pp. 215-229, Feb. 2008.