Published February 13, 2024 | Version v1
Dataset Restricted

Dataset related to article "Diagnostic accuracy and safety of EUS-guided end-cutting fine-needle biopsy needles for tissue sampling of abdominal and mediastinal lymphadenopathies: a prospective multicenter series"

Description

This record contains raw data related to article “Diagnostic accuracy and safety of EUS-guided end-cutting fine-needle biopsy needles for tissue sampling of abdominal and mediastinal lymphadenopathies: a prospective multicenter series"

Background and aims: The role of the newer EUS fine-needle biopsy needles in lymphadenopathies (LAs) is still under evaluation. We aimed to evaluate the diagnostic accuracy and adverse event rate of EUS-guided fine-needle biopsy sampling (EUS-FNB) in diagnosing LAs.

Methods: From June 2015 to June 2022, all patients referred to 4 institutions for EUS-FNB of mediastinal and abdominal LAs were enrolled. Twenty-two-gauge Franseen tip or 25-gauge fork-tip needles were used. The criterion standard for positive results was surgery or imaging and clinical evolution over a follow-up of at least 1 year.

Results: One hundred consecutive patients were enrolled, consisting of those with a new diagnosis of LA (40%), presence of LA with a previous history of neoplasia (51%), or suspected lymphoproliferative disease (9%). EUS-FNB was technically feasible in all LA patients with 2 to 3 passes (mean, 2.62 ± .93). The overall sensitivity, positive predictive value, specificity, negative predictive value, and accuracy for EUS-FNB were 96.20%, 100%, 100%, 87.50%, and 97.00%, respectively. Histologic analysis was feasible in 89% of cases. Cytologic evaluation was performed in 67% of specimens. A statistical difference between the accuracy of the 22-gauge or 25-gauge needle (P = .63) was not found. A subanalysis on lymphoproliferative disease revealed a sensitivity and accuracy of 89.29% and 90.0%, respectively. No adverse events were recorded.

Conclusions: EUS-FNB with new end-cutting needles is a valuable and safe method to diagnose LAs. The high quality of histologic cores and the good amount of tissue allowed a complete immunohistochemical analysis of metastatic LAs and precise subtyping of the lymphomas. (Clinical trial registration number: NCT02855151.).

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

This set of raw data is accessible under request because they include sensitive data.

Please provide details about your request

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is supplemented by
Publication: 36990125 (PMID)
Publication: 10.1016/j.gie.2023.03.018 (DOI)