Published August 24, 2008
| Version 1510
Journal article
Open
Development of an Autonomous Greenhouse Gas Monitoring System
Authors/Creators
Description
This paper describes the designs of a first and second
generation autonomous gas monitoring system and the successful
field trial of the final system (2nd generation). Infrared sensing
technology is used to detect and measure the greenhouse gases
methane (CH4) and carbon dioxide (CO2) at point sources. The
ability to monitor real-time events is further enhanced through the
implementation of both GSM and Bluetooth technologies to
communicate these data in real-time. These systems are robust,
reliable and a necessary tool where the monitoring of gas events in
real-time are needed.
Files
1510.pdf
Additional details
References
- C. M. McGraw, S. E. Stitzel, J. Cleary, C. Slater, and D. Diamond (2007) "Autonomous microfluidic system for phosphate detection" Talanta 71: 1180-1185.
- E. Aitchison, "Methane generation from UK landfill sites and its use as an energy resource" Energy Conversion and Management 1996, 37(6-8), 1111-1116).
- K. Spokas, J. Bogner, J. P. Chanton, M. Morcet, C. Aran, C. Graff et al. (2006) "Methane mass balance at three landfill sites: What is the efficiency of capture by gas collection systems?" Waste Management 26(5): 516-525.
- IRgaskIT Carbon Dioxide Monitor Operating Manual V1.2 supplied by Edinburgh Instruments Limited 2006.