In this study, we present data from high-throughput cyclic voltammetry (CV) test, derived by our digital workflow, Auto-MISCHBARES, complemented by XPS analysis. This research is part of the pre-print publication named "Autonomous millimeter scale high throughput battery research system", showcasing Cathode Electrolyte Interphase (CEI) investigation. The electrolyte used for this experiment is 1M of LiPF6 solution in an Ethylene Carbonate (EC): Ethyl Methyl Carbonate (EMC) mixture with a 3:7 weight ratio, along with LFP as our electrode material. The CV tests were conducted through a high-throughput sequential process for two cycles, each with varying stop potentials. After the experimentation phase, XPS analysis was applied to characterize the synthesized CEI.