COMPARATIVE HOT CORROSION BEHAVIOR OF HVOF AND PLASMA SPRAYED NI20CR COATED T-22 STEEL IN ACTUAL COAL FIRED BOILER ENVIRONMENT
Authors/Creators
- 1. 1Research Scholar, I.K.G.P.T.U., Kapurthala-144001, India
- 2. 2Mechanical Engineering,I.K.G.P.T.U. Main Campus, Kapurthala-144001, India
Description
Thermal spray process is commonly used to protect high temperature corrosions in coal or oil fired boiler due to the effectiveness of the technique. In this study the corrosion resistance of Ni20Cr coating sprayed by two thermal spray processes is compared. The HVOF and Plasma spray processes were used to deposit Ni20Cr coating powder on SA-213 (T22) boiler steel. Studies were performed on coated and bare specimens exposed to actual boiler environment at an average temperature of 700oC under cyclic conditions. The weights gain/lost analysis as well as thickness monitoring of unreacted portion was used to measure the corrosion kinetics in actual boiler environment. The XRD, FE-SEM/EDS and X-Ray mapping analysis were done to characterize the hot corrosion behavior in the given environments. The major phases formed in the Ni20Cr coated specimens are oxides of Ni, Cr, which are suggested to be protective barrier between the corrosive environment and substrate. It is found that Ni20Cr coated specimens offered high resistance to corrosion as compared to uncoated/bare specimen. An overall analysis of thermogravimetric, thickness monitoring, XRD and FE-SEM analysis showed that the HVOF spray process should be the better option for the given environment than Plasma spray process.