Magnetic remanence (SRM-longcore) Magnetic remanence was measured on section halves (and rarely on whole-round sections) using a 2G Enterprises 760R cryogenic magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization steps were performed on the samples by alternating field (AF) demagnetizer coils mounted in-line within the instrument. Data File format Exp: expedition number Site: site number Hole: hole number Core: core number Type: type indicates the coring tool used to recover the core (typical types are F, H, R, X). Sect: section number A/W: archive (A) or working (W) section half. Offset (cm): position of the observation made, measured relative to the top of the section. Depth CSF-A (m): location of the observation expressed relative to the top of a hole. Depth [other] (m): location of the observation expressed relative to the top of a hole. The location is presented in a scale selected by the science party or the report user. Treatment type: refers to type of remanent magnetization measured, such as NRM, ARM, and IRM. Treatment value: level of treatment that was applied to the sample being measured. Inclination background & drift corrected (deg): inclination computed with background and drift correction. Declination background & drift corrected (deg): declination computed with background and drift correction. Intensity background & drift corrected (A/m): intensity computed with background and drift correction. Inclination raw (deg): inclination computed from magnetic moment data. Declination raw (deg) declination computed from magnetic moment data. Intensity raw (A/m): intensity computed from magnetic moment data. Magnetic moment x (Am^2): magnetic moment raw data from X SQUID axis, with sign corrected to match IODP orientation conventions Magnetic moment y (Am^2): magnetic moment raw data from Y SQUID axis, with sign corrected to match IODP orientation conventions Magnetic moment z (Am^2): magnetic moment raw data from Z SQUID axis, with sign corrected to match IODP orientation conventions Sample orientation: orientation of section measured (e.g., archive or working). Raw data filename: SRM raw data file. SRM background filename: SRM background with tray data file. Configuration filename: SRM instrument configuration file. Instrument: abbreviation for the magnetometer used to make this measurement (SRM). Timestamp (UTC): time file was uploaded, which is typically a few minutes to hours after data were acquired. Text ID: automatically generated unique database identifier for a sample, visible on printed labels. Test No: unique number associated with the instrument measurement steps that produced these data. Sample comments: observations recorded about the sample itself. Test comments: observations about a measurement or the measurement process; some measurement observations may be under Result comments. Result comments: observations about a measurement or the measurement process; some measurement observations may be under Test comments.