------------------------ Recorded data structure ------------------------ Dataset Title: Operation SCADA Data of an Urban Small Wind Turbine in São Paulo, Brazil Doi:10.5281/zenodo.7348454 1 record per minute. The files in the dataset are named as "data_swt_iee_usp_YYYY.csv" where YYYY is the referring year. In the files, the semicolon symbol (;) is used as a column separator, while the dot symbol (.) represents the decimal separator. The first line on each year-based file represents the header table description of the data columns, as presented below. Listed below is the meaning of each column in the data file: -------------------------------------------------------------------------------------------------------- Column Record Description -------------------------------------------------------------------------------------------------------- A Log Time Local time YYYY:MM:DD:HH:MM:SS.SSS B SN# Serial number of the SWT. Value = 107605 C Software rev The inverter firmware version . Value = 202 D opversion The software version. Value = 300 E Inv Time Decimal Timestamp by the inverter (GMT) F watt-hours Accumulated energy production (Wh) G Voltage In Voltage generated by the rotor (V) H Voltage DC Bus Voltage dc bus in the inverter (V) I Voltage L1 Grid voltage, phase L1 (V) J Voltage L2 Grid voltage, phase L2 (V) K voltage rise Common voltage rise (V) L min v from rpm Minimum voltage for the correspondent RPM (V) M Current out Current ac (A) N Power out Power output of the inverter (W) O Power reg Power from generator (W) P Power max Inverter maximum power production (W) Q Line Frequency Frequency at the grid (Hz) R Inverter Frequency Frequency at the inverter (Hz) S Line Resistance L ine impedance (Ohm) T RPM Blade Rotations per minute U Windspeed (ref) Integer value of windspeed from RPM (m/s) V TargetTSR Assigned tip speed ratio W Ramp RPM Assigned rotational speed X Boost pulswidth Pulse modulation at the inverter Y Max BPW Maximum pulse modulation at the inverter Z current amplitude Integer number proportional of current output AA T1 Temperature at Heatsink T1 (Celsius) AB T2 Temperature at Heatsink T2 (Celsius) AC T3 Temperature at the nacelle (Celsius) AD Event count Cumulative count of events AE Last event code Code of the last event AF Event status Code status of the current event AG Event value Code value of the current event AH Turbine status Current status code of turbine AI Grid status Code status of the connected grid AJ System status Code status of the system AK Slave Status Code status of the system AL Access Status Access level (signal strength) AM Timer Timer countdown to zero after some event --------------------------------------------------------------------------------------------------------