Published December 2, 2019 | Version v1
Journal article Open

A VALIDATED CHIRAL HPLC METHOD FOR THE ENANTIOMERIC PURITY OF TRELAGLIPTIN

  • 1. 1Stereokem Private Limited. Plot No-36/A, IDA, Uppal, Hyderabad, Telangana, India. 2Chaitanya Bharathi Institute of Technology, Gandipet,Hyderabad, Telangana, India.

Description

An accurate,precise,simple and rugged  Chiral HPLC method has been developed and validated for the quantitation of (S)-isomer in Trelagliptin. The enantiomeric separation of Trelagliptin was achieved  Chiral pak AD-3 (250×4.6mm, 3μm) column. The ratio of Hexane,ethanol and diethyl amine (70:30:0.1)in the mobile phase were optimized to obtain the best separation. UV detection was performed at 275 nm. The method is linear over a range of LOQ – 150 % of (S)-isomer. The mean recovery of (S)-isomer was found to be in the range of 95–105%. The method is simple, rapid, accurate, selective and precise, useful in the quality control of bulk manufacturing.

Files

191011.pdf

Files (692.1 kB)