There is a newer version of the record available.

Published May 21, 2024 | Version v1
Conference paper Open

A Simplified Setup for Passive Intermodulation Measurement

  • 1. Czech Metrology Institute
  • 2. ROR icon Physikalisch-Technische Bundesanstalt

Description

This paper presents a simplified setup for measurement of passive intermodulation products using a single amplifier, bank of filters and a duplexer. It is shown that this proposed setup brings some advantages compared to the classic two-amplifier setup. The measured PIM levels obtained from this simplified setup were verified through a comparison with measurement results yielded using a commercial PIM analyzer. A good agreement between both measurements was achieved. The reported measurement uncertainty is 2.5 dB for the measured PIM level -80 dB(mW).

Files

I2MTC_2024_PIM_measurement.pdf

Files (1.3 MB)

Name Size Download all
md5:69234c9ada1ba8b7a82d003a4cae05a2
1.3 MB Preview Download

Additional details

Related works

Is source of
Conference paper: 10.1109/I2MTC60896.2024.10560706 (DOI)