Local Calibration of TDR Measurements for Determining Water and Organic Carbon Contents of Peaty Soils
Authors/Creators
Description
Time domain reflectometry (TDR) measurements of the volumetric water content (θ) of soils are based on the dielectric permittivity (ε), relating ε to θ, using an empirical calibration function. Accurate determination of θ for peaty soils is vital but complicated by the complexity of organic soils and the lack of a general calibration model. Site-specific calibration models were developed to determine θ from TDR measurements for a heterogenous peatland across gradients of peat decomposition and organic carbon (OC) content; derived by soil organic matter conversion. The possibility of predicting OC contents based on the corrected θ (θcor); ε; electrical impedance (Ζ); and a categorical predictor variable was explored. The application of plot-specific and local area calibration models resulted in similar results. Compared to common calibrations, the threshold for accurate determination of θ was at ε = 5; with higher ε underestimating θ by up to 25%. Including the von Post degree of peat humification as a bioindicator, the OC content could be modelled across the area and the full range of θ with an accuracy of ±1.2% for 496 measurements. In conclusion, a strong indication was found for determining OC in peatlands in situ using TDR and a site-specific calibration model for θ together with indices of peat decomposition.
This publication is supported by the WET HORIZONS project
Files
Claudia Nielson Soil Science Publication.pdf
Files
(1.7 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:2e720416bfc283b8be0373d78018fb27
|