Journal article Open Access

Comparing the resolution of magnetic force microscopes using the CAMST reference samples

Abelmann, Leon; Porthun, Steffen; Haast, Marc; Lodder, Cock; Moser, Andreas; Best, Margaret E.; van Schendel, Pieter J. A.; Stiefel, Bruno; Hug, Hans J.; Heydon, Greg P.; Farley, Andrew; Hoon, Steve R.; Pfaffelhuber, Thomas; Proksch, Roger; Babcock, Ken


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://zenodo.org/record/889513</identifier>
  <creators>
    <creator>
      <creatorName>Abelmann, Leon</creatorName>
      <givenName>Leon</givenName>
      <familyName>Abelmann</familyName>
    </creator>
    <creator>
      <creatorName>Porthun, Steffen</creatorName>
      <givenName>Steffen</givenName>
      <familyName>Porthun</familyName>
    </creator>
    <creator>
      <creatorName>Haast, Marc</creatorName>
      <givenName>Marc</givenName>
      <familyName>Haast</familyName>
    </creator>
    <creator>
      <creatorName>Lodder, Cock</creatorName>
      <givenName>Cock</givenName>
      <familyName>Lodder</familyName>
    </creator>
    <creator>
      <creatorName>Moser, Andreas</creatorName>
      <givenName>Andreas</givenName>
      <familyName>Moser</familyName>
    </creator>
    <creator>
      <creatorName>Best, Margaret E.</creatorName>
      <givenName>Margaret E.</givenName>
      <familyName>Best</familyName>
    </creator>
    <creator>
      <creatorName>van Schendel, Pieter J. A.</creatorName>
      <givenName>Pieter J. A.</givenName>
      <familyName>van Schendel</familyName>
    </creator>
    <creator>
      <creatorName>Stiefel, Bruno</creatorName>
      <givenName>Bruno</givenName>
      <familyName>Stiefel</familyName>
    </creator>
    <creator>
      <creatorName>Hug, Hans J.</creatorName>
      <givenName>Hans J.</givenName>
      <familyName>Hug</familyName>
    </creator>
    <creator>
      <creatorName>Heydon, Greg P.</creatorName>
      <givenName>Greg P.</givenName>
      <familyName>Heydon</familyName>
    </creator>
    <creator>
      <creatorName>Farley, Andrew</creatorName>
      <givenName>Andrew</givenName>
      <familyName>Farley</familyName>
    </creator>
    <creator>
      <creatorName>Hoon, Steve R.</creatorName>
      <givenName>Steve R.</givenName>
      <familyName>Hoon</familyName>
    </creator>
    <creator>
      <creatorName>Pfaffelhuber, Thomas</creatorName>
      <givenName>Thomas</givenName>
      <familyName>Pfaffelhuber</familyName>
    </creator>
    <creator>
      <creatorName>Proksch, Roger</creatorName>
      <givenName>Roger</givenName>
      <familyName>Proksch</familyName>
    </creator>
    <creator>
      <creatorName>Babcock, Ken</creatorName>
      <givenName>Ken</givenName>
      <familyName>Babcock</familyName>
    </creator>
  </creators>
  <titles>
    <title>Comparing the resolution of magnetic force microscopes using the CAMST reference samples</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2015</publicationYear>
  <dates>
    <date dateType="Issued">2015-04-14</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/889513</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1016/s0304-8853(98)00281-9</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">A set of reference samples for comparing the results obtained with different magnetic force microscopes (MFM) has been prepared. These samples consist of CoNi/Pt magneto-optic multilayers with different thicknesses. The magnetic properties of the multilayer are tailored in such a way that a very fine stripe domain structure occurs in remanence. On top of this intrinsic domain structure, bits were written thermomagnetically using different laser powers. These samples have been imaged in six different laboratories employing both home-built and commercial magnetic force microscopes. The resolution obtained with these different microscopes, tips and measurement methods varies between 30 and 100 nm. ; Full-text of this article is not available in this e-prints service. This article was originally published in Journal of magnetism and magnetic materials, published by and copyright Elsevier.</description>
  </descriptions>
</resource>
186
188
views
downloads
Views 186
Downloads 188
Data volume 246.8 MB
Unique views 177
Unique downloads 172

Share

Cite as