Conference paper Open Access

Maximizing the penetration of inverter-based generation on large transmission systems: the MIGRATE project

Debry, Marie-Sophie; Denis, Guillaume; Prevost, Thibault; Xavier, Florent; Menze, Andreas


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[1]	Wind and Solar Plant Collector Design Working Group, «Technical Paper Compendium PES-TPC3,» IEEE Power &amp; Energy Society, Boston, US, August 2016</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">P. Kundur, Power System Stability and Control, The EPRI Power System Engineering Series, McGraw-Hill, 1994</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[3]	A. Junyent-Ferré, Y. Pipelzadeh, and T. C. Green, "Blending HVDC-link energy storage and offshore wind turbine inertia for fast frequency response," IEEE Transactions on Substainable Energy, Vol. 6, No. 3, July 2015</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[4]	G. Denis, T. Prevost, P. Panciatici, X. Kestelyn, F. Colas et X. Guillaud, «Review on potential strategies for transmission grid operations based on power electronics interfaced voltage sources,» chez IEEE Power &amp; Energy General Meeting, Denver, 2015</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[5]	Keller J., Kroposki B., Understanding Fault Characteristics of Inverter-Based Distributed Energy resources, NREL/TP-550-46698, January 2010</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[6]	Katiraei, F., &amp; Iravani, M. R. (2006). Power management strategies for a microgrid with multiple distributed generation units. IEEE transactions on power systems, 21(4), 1821-1831R</subfield>
  </datafield>
  <datafield tag="999" ind1="C" ind2="5">
    <subfield code="x">[7]	Liu, H., &amp; Sun, J. (2011, October). A study of offshore wind HVDC system stability and control. In Proceedings of 10th International Workshop on Large-Scale Integration of Wind Power into Power Systems as well as on Transmission Networks for Offshore Wind Power Plans</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Power electronic</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Converter</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Frequency</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Stability</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Grid forming</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Renewable energy</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Transmission system</subfield>
  </datafield>
  <controlfield tag="005">20200120174043.0</controlfield>
  <controlfield tag="001">807094</controlfield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="d">14-15 November 2016</subfield>
    <subfield code="a">6th Solar Integration Workshop</subfield>
    <subfield code="c">Vienna</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Réseau de Transport d'Electricité</subfield>
    <subfield code="a">Denis, Guillaume</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Réseau de Transport d'Electricité</subfield>
    <subfield code="a">Prevost, Thibault</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Réseau de Transport d'Electricité</subfield>
    <subfield code="a">Xavier, Florent</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">TenneT Offshore GmbH</subfield>
    <subfield code="a">Menze, Andreas</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">246977</subfield>
    <subfield code="z">md5:8b47876485820c5d5d57334b35143fef</subfield>
    <subfield code="u">https://zenodo.org/record/807094/files/Maximizing the penetration of inverter-based generation on large transmission systems the MIGRATE project_Zenodo version.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="y">Conference website</subfield>
    <subfield code="u">http://solarintegrationworkshop.org/vienna2016/</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2016-11-14</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="o">oai:zenodo.org:807094</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Réseau de Transport d'Electricité</subfield>
    <subfield code="a">Debry, Marie-Sophie</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Maximizing the penetration of inverter-based generation on large transmission systems: the MIGRATE project</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">691800</subfield>
    <subfield code="a">Massive InteGRATion of power Electronic devices</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;Renewable generation is mainly connected through converters. It can provide more and more services to the grid such as voltage support or frequency control. However, these services may not be sufficient for extremely high penetrations. As the share of such generating units is growing rapidly, some synchronous areas could in the future occasionally be operated without synchronous machines. In such conditions, system stability will have to be ensured with the same level of reliability as today. Presently, operation of power systems is based on the presence of synchronous machines. Frequency is linked to the balance between load and generation via the rotating masses equation. This will not be inherently valid for grids without synchronous machines. The matter of operating a network with 100 % power electronics is quite well resolved for small isolated systems. The same doesn’t apply for large transmission systems where grid topology and power injections are highly variable and are not known at every moment by all system components or even by a centralized entity. This paper describes the research that needs to be achieved to remove barriers for high penetrations of converters.&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="n">doi</subfield>
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.5281/zenodo.807093</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.5281/zenodo.807094</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
</record>
109
326
views
downloads
All versions This version
Views 109109
Downloads 326323
Data volume 80.5 MB79.8 MB
Unique views 104104
Unique downloads 309307

Share

Cite as