Journal article Open Access

METHOD DEVELOPMENT AND VALIDATION OF FIVE NITROSAMINES IMPURITIES CONTENT IN TELMISARTAN DRUG SUBSTANCE BY GC-MS/MS

*Harendra Singh, * Dr. Rahul Kumar


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="DOI">10.5281/zenodo.6900807</identifier>
  <creators>
    <creator>
      <creatorName>*Harendra Singh, * Dr. Rahul Kumar</creatorName>
      <givenName>* Dr. Rahul Kumar</givenName>
      <familyName>*Harendra Singh</familyName>
    </creator>
  </creators>
  <titles>
    <title>METHOD DEVELOPMENT AND VALIDATION OF FIVE NITROSAMINES IMPURITIES CONTENT IN TELMISARTAN DRUG SUBSTANCE BY GC-MS/MS</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2022</publicationYear>
  <dates>
    <date dateType="Issued">2022-07-25</date>
  </dates>
  <resourceType resourceTypeGeneral="JournalArticle"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/6900807</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.6900806</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;&lt;em&gt;A proficient GC-MS/MSS method was developed for determination of N-Nitrosodimethylamine, N-Nitrosodiethylamine, N-Nitrosodiisopropylamine, N-Nitrosoisopropylethylamine, N-Nitrosodibutylamine impurities in Telmisartan Drug Substance using column Rtx-5 Amine (30m length X 0.32mm diameter) 1.5&amp;micro;m film thickness, Part No.: 12369, Make: Restek.&amp;nbsp; Helium is used as Carrier gas at with Linear velocity of 44.3 cm/sec. The proposed method was validated for System suitability, Specificity, Linearity, LOD and LOQ, Method precision, Intermediate precision and Recovery. All the parameters were found within the acceptable limits. Linearity in the range of LOQ to 150% for each impurity. The established methodology was commercially useful, specific, accurate, precise and suitable for the analysis of Nitrosamines impurities in Telmisartan drug substance &lt;/em&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;em&gt;Keywords&lt;/em&gt;&lt;/strong&gt;&lt;em&gt;: Gas chromatography with mass spectrometry (GC-MS/MS), Telmisartan drug substance, Nitrosamine impurities, ICH guideline and Method Validation.&lt;/em&gt;&lt;/p&gt;</description>
  </descriptions>
</resource>
45
11
views
downloads
All versions This version
Views 4545
Downloads 1111
Data volume 11.3 MB11.3 MB
Unique views 4343
Unique downloads 1111

Share

Cite as