Dataset Open Access

DCE-MRI prostate images

Lemaitre, Guillaume; Marti, Robert; Meriaudeau, Fabrice


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-3" xsi:schemaLocation="http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd">
  <identifier identifierType="DOI">10.5281/zenodo.61163</identifier>
  <creators>
    <creator>
      <creatorName>Lemaitre, Guillaume</creatorName>
      <affiliation>Universite de Bourgogne, Universitat de Girona</affiliation>
    </creator>
    <creator>
      <creatorName>Marti, Robert</creatorName>
      <affiliation>Universitat de Girona</affiliation>
    </creator>
    <creator>
      <creatorName>Meriaudeau, Fabrice</creatorName>
      <affiliation>Universite de Bourgogne</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Dce-Mri Prostate Images</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2016</publicationYear>
  <subjects>
    <subject>dce-mri</subject>
    <subject>normalization</subject>
    <subject>prostate</subject>
    <subject>cancer</subject>
    <subject>mp-MRI</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2016-08-30</date>
  </dates>
  <resourceType resourceTypeGeneral="Dataset"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/61163</alternateIdentifier>
  </alternateIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/odc-odbl">Open Data Commons Open Database License 1.0</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;A 3mm slice fat-suppressed T2W fast spin-echo sequence (TR/TE/ETL: 3400 ms/85 ms/13) is used to acquire images in sagittal and oblique coronal planes, the latter planes being orientated perpendicular or parallel to the prostate PZ – rectal wall axis. Three-dimensional T2W fast spin-echo (TR/TE/ETL: 3600 ms}/143 ms/109, slice thickness: 1.25 mm) images are then acquired in an oblique axial plane.The nominal matrix and FoV of the 3D T2W fast spin-echo images are 320x256 and 280x240 mm&lt;sup&gt;2&lt;/sup&gt;, respectively, thereby affording sub-millimetric pixel resolution within the imaging plane.&lt;br&gt;
DCE-MRI is performed using a fat suppressed 3D T$_1$ VIBE sequence (TR/TE/Flip angle: 3.25 ms/1.12 ms/10 degrees; Matrix: 256x192; FoV: 280x210 (with 75% rectangular FoV); slab of 16 partitions of 3.5 mm thickness; temporal resolution: 6 s/slab over approximately 5 min). A power injector (Medrad, Indianola, USA) is used to provide a bolus injection of Gd-DTPA (Dotarem, Guerbet, Roissy, France) at a dose of 0.2 ml Gd-DTPA/kg of body weight.&lt;/p&gt;</description>
  </descriptions>
</resource>

Share

Cite as