Journal article Open Access

Simulation of 28 Element Ultrasound Transducer for Non-Destructive Evaluation (NDE) Applications

Kiran Kale


DCAT Export

<?xml version='1.0' encoding='utf-8'?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:adms="http://www.w3.org/ns/adms#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dct="http://purl.org/dc/terms/" xmlns:dctype="http://purl.org/dc/dcmitype/" xmlns:dcat="http://www.w3.org/ns/dcat#" xmlns:duv="http://www.w3.org/ns/duv#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:frapo="http://purl.org/cerif/frapo/" xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#" xmlns:gsp="http://www.opengis.net/ont/geosparql#" xmlns:locn="http://www.w3.org/ns/locn#" xmlns:org="http://www.w3.org/ns/org#" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:prov="http://www.w3.org/ns/prov#" xmlns:rdfs="http://www.w3.org/2000/01/rdf-schema#" xmlns:schema="http://schema.org/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:vcard="http://www.w3.org/2006/vcard/ns#" xmlns:wdrs="http://www.w3.org/2007/05/powder-s#">
  <rdf:Description rdf:about="https://zenodo.org/record/5840182">
    <dct:identifier rdf:datatype="http://www.w3.org/2001/XMLSchema#anyURI">https://zenodo.org/record/5840182</dct:identifier>
    <foaf:page rdf:resource="https://zenodo.org/record/5840182"/>
    <dct:creator>
      <rdf:Description>
        <rdf:type rdf:resource="http://xmlns.com/foaf/0.1/Agent"/>
        <foaf:name>Kiran Kale</foaf:name>
        <org:memberOf>
          <foaf:Organization>
            <foaf:name>Department Electronics and Communication, Amity University, Maharashtra Mumbai, Maharashtra, India</foaf:name>
          </foaf:Organization>
        </org:memberOf>
      </rdf:Description>
    </dct:creator>
    <dct:title>Simulation of 28 Element Ultrasound Transducer for Non-Destructive Evaluation (NDE) Applications</dct:title>
    <dct:publisher>
      <foaf:Agent>
        <foaf:name>Zenodo</foaf:name>
      </foaf:Agent>
    </dct:publisher>
    <dct:issued rdf:datatype="http://www.w3.org/2001/XMLSchema#gYear">2020</dct:issued>
    <dcat:keyword>Non-Destructive Evaluation (NDE), Quantitative Ultrasound Wave, k-Wave, Material Density, Wave Propagation, Simulation Environment, Time of Flight (TOF)</dcat:keyword>
    <dct:subject>
      <skos:Concept>
        <skos:prefLabel>2277-3878</skos:prefLabel>
        <skos:inScheme>
          <skos:ConceptScheme>
            <dct:title>issn</dct:title>
          </skos:ConceptScheme>
        </skos:inScheme>
      </skos:Concept>
    </dct:subject>
    <dct:subject>
      <skos:Concept>
        <skos:prefLabel>100.1/ijrte.B2107078219</skos:prefLabel>
        <skos:inScheme>
          <skos:ConceptScheme>
            <dct:title>handle</dct:title>
          </skos:ConceptScheme>
        </skos:inScheme>
      </skos:Concept>
    </dct:subject>
    <schema:sponsor>
      <rdf:Description>
        <rdf:type rdf:resource="http://xmlns.com/foaf/0.1/Agent"/>
        <foaf:name>Blue Eyes Intelligence Engineering and Sciences Publication(BEIESP)</foaf:name>
        <org:memberOf>
          <foaf:Organization>
            <foaf:name>Publisher</foaf:name>
          </foaf:Organization>
        </org:memberOf>
      </rdf:Description>
    </schema:sponsor>
    <dct:issued rdf:datatype="http://www.w3.org/2001/XMLSchema#date">2020-11-30</dct:issued>
    <dct:language rdf:resource="http://publications.europa.eu/resource/authority/language/ENG"/>
    <owl:sameAs rdf:resource="https://zenodo.org/record/5840182"/>
    <adms:identifier>
      <adms:Identifier>
        <skos:notation rdf:datatype="http://www.w3.org/2001/XMLSchema#anyURI">https://zenodo.org/record/5840182</skos:notation>
        <adms:schemeAgency>url</adms:schemeAgency>
      </adms:Identifier>
    </adms:identifier>
    <dct:relation rdf:resource="http://issn.org/resource/ISSN/2277-3878"/>
    <owl:sameAs rdf:resource="https://doi.org/10.35940/ijrte.D5012.119420"/>
    <dct:description>&lt;p&gt;Quantitative ultrasound based Non-Destructive Evaluation (NDE) is one of the leading test procedures used in testing of finished products in manufacturing industry. It can detect surface as well as subsurface flaws accurately. It is also employed in medical diagnostic for various purposes. The main objective of this paper is to simulate 28 element ultrasound transducer pair for through transmission testing procedure. The simulation is done using k-Wave toolbox (open source toolbox) and MATLAB. The simulation results show that the received signal strength and resolution is far more improved over single and dual element transducer probes available in the market. The simulation of wave propagation through three layered aluminum material is also shown in the results. Based on results, it can be concluded that 28 element transducer pair are the optimum solution for NDE evaluation challenges with reference to cost, size, and design complexity.&lt;/p&gt;</dct:description>
    <dct:accessRights rdf:resource="http://publications.europa.eu/resource/authority/access-right/PUBLIC"/>
    <dct:accessRights>
      <dct:RightsStatement rdf:about="info:eu-repo/semantics/openAccess">
        <rdfs:label>Open Access</rdfs:label>
      </dct:RightsStatement>
    </dct:accessRights>
    <dct:license rdf:resource="https://creativecommons.org/licenses/by/4.0/legalcode"/>
    <dcat:distribution>
      <dcat:Distribution>
        <dcat:accessURL rdf:resource="https://doi.org/10.35940/ijrte.D5012.119420"/>
        <dcat:byteSize>194977</dcat:byteSize>
        <dcat:downloadURL rdf:resource="https://zenodo.org/record/5840182/files/D5012119420.pdf"/>
        <dcat:mediaType>application/pdf</dcat:mediaType>
      </dcat:Distribution>
    </dcat:distribution>
  </rdf:Description>
</rdf:RDF>
40
16
views
downloads
Views 40
Downloads 16
Data volume 3.1 MB
Unique views 31
Unique downloads 14

Share

Cite as