Journal article Open Access

Optimal Placement of DG and FCL Sizing By using Fuzzy-Jaya Algorithm

Vasavi.C; T.Gowri Manohar


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://zenodo.org/record/5832223</identifier>
  <creators>
    <creator>
      <creatorName>Vasavi.C</creatorName>
      <affiliation>Research Scholar, Dept. of Electrical and Electronics  Engineering, Sri Venkateswara University, Tirupati (A.P), India.</affiliation>
    </creator>
    <creator>
      <creatorName>T.Gowri Manohar</creatorName>
      <affiliation>Dept. of. Electrical and Electronics  Engineering, Sri Venkateswara University, Tirupati (A.P), India.</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Optimal Placement of DG and FCL Sizing By  using Fuzzy-Jaya Algorithm</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2021</publicationYear>
  <subjects>
    <subject>Controlled Impedance FCL (CI-FCL), Distributed Generation, JAYA Algorithm, Fuzzy Approach.</subject>
    <subject subjectScheme="issn">2277-3878</subject>
    <subject subjectScheme="handle">100.1/ijrte.A57400510121</subject>
  </subjects>
  <contributors>
    <contributor contributorType="Sponsor">
      <contributorName>Blue Eyes Intelligence Engineering and Sciences Publication(BEIESP)</contributorName>
      <affiliation>Publisher</affiliation>
    </contributor>
  </contributors>
  <dates>
    <date dateType="Issued">2021-05-30</date>
  </dates>
  <language>en</language>
  <resourceType resourceTypeGeneral="JournalArticle"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/5832223</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="ISSN" relationType="IsCitedBy" resourceTypeGeneral="JournalArticle">2277-3878</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.35940/ijrte.A5740.0510121</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;Smart grid is the most significant topic in power system due to numerous benefits. Smart grid is the integration of distributed generation. DG plays an important role in different configurations either in grid connected mode or islanded mode. Multiple configurations will result in fault currents this may lead to damage to the existing protective devices. In this paper Fuzzy is used to optimally locate DG and Jaya a new optimization technique is adapted to size the Fault current limiter. Controlled Impedance Fault Current Limiter (CI-FCL) is used to reduce the magnitude of fault current and also avoid false tripping of protective devices. A program is developed in MATLAB 2017Ra to test the IEEE 33 and 69 bus distribution systems the results are compared with the analytical PSO method. The results shows the effectiveness of Jaya Algorithm and also reduces the computational time and no. of iterations.&lt;/p&gt;</description>
  </descriptions>
</resource>
22
27
views
downloads
Views 22
Downloads 27
Data volume 17.4 MB
Unique views 18
Unique downloads 25

Share

Cite as