Journal article Open Access

Deep learning-based fully automated Z-axis coverage range definition from scout scans to eliminate overscanning in chest CT imaging

Habib Zaidi; Yazdan Salimi


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2021-11-06</subfield>
  </datafield>
  <controlfield tag="005">20211207134845.0</controlfield>
  <controlfield tag="001">5764101</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="o">oai:zenodo.org:5764101</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;&lt;strong&gt;Background:&amp;nbsp;&lt;/strong&gt;Despite the prevalence of chest CT in the clinic, concerns about unoptimized protocols delivering high radiation doses to patients still remain. This study aimed to assess the additional radiation dose associated with overscanning in chest CT and to develop an automated deep learning-assisted scan range selection technique to reduce radiation dose to patients.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&amp;nbsp;&lt;/strong&gt;A significant overscanning range (31 &amp;plusmn; 24) mm was observed in clinical setting for over 95% of the cases. The average Dice coefficient for lung segmentation was 0.96 and 0.97 for anterior-posterior (AP) and lateral projections, respectively. By considering the exact lung coverage as the ground truth, and AP and lateral projections as input, The DL-based approach resulted in errors of 0.08 &amp;plusmn; 1.46 and - 1.5 &amp;plusmn; 4.1 mm in superior and inferior directions, respectively. In contrast, the error on external scout views was - 0.7 &amp;plusmn; 4.08 and 0.01 &amp;plusmn; 14.97 mm for superior and inferior directions, respectively.The ED reduction achieved by automated scan range selection was 21% in the test group. The evaluation of a large multi-centric chest CT dataset revealed unnecessary ED of more than 2 mSv per scan and 67% increase in the thyroid absorbed dose.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&amp;nbsp;&lt;/strong&gt;The proposed DL-based solution outperformed previous automatic methods with acceptable accuracy, even in complicated and challenging cases. The generizability of the model was demonstrated by fine-tuning the model on AP scout views and achieving acceptable results. The method can reduce the unoptimized dose to patients by exclunding unnecessary organs from field of view.&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Deep learning-based fully automated Z-axis coverage range definition from scout scans to eliminate overscanning in chest CT imaging</subfield>
    <subfield code="a">Yazdan Salimi</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">4267880</subfield>
    <subfield code="z">md5:516e83b4d38a2c0d77c8330febb482e6</subfield>
    <subfield code="u">https://zenodo.org/record/5764101/files/InsightsImaging2021.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Geneva University Hospital</subfield>
    <subfield code="0">(orcid)0000-0001-7559-5297</subfield>
    <subfield code="a">Habib Zaidi</subfield>
  </datafield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">CT; Chest imaging; Deep learning; Overscanning; Radiation dose</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1186/s13244-021-01105-3</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Deep learning-based fully automated Z-axis coverage range definition from scout scans to eliminate overscanning in chest CT imaging</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">945196</subfield>
    <subfield code="a">Radiation risk appraisal for detrimental effects from medical exposure during management of patients with lymphoma or brain tumour</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
</record>
41
20
views
downloads
Views 41
Downloads 20
Data volume 85.4 MB
Unique views 37
Unique downloads 19

Share

Cite as