Zenodo.org will be unavailable for 2 hours on September 29th from 06:00-08:00 UTC. See announcement.

Journal article Open Access

Automatic Switching of Three Phase Induction Motor during Fault Condition

Aswin.S; Aswin.S; Jagadesh.P; Keerthi Aravind.S.P; Kesava Suriyan.P; Baranilingesan.


Dublin Core Export

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:contributor>Blue Eyes Intelligence Engineering and Sciences Publication(BEIESP)</dc:contributor>
  <dc:creator>Aswin.S</dc:creator>
  <dc:creator>Aswin.S</dc:creator>
  <dc:creator>Jagadesh.P</dc:creator>
  <dc:creator>Keerthi Aravind.S.P</dc:creator>
  <dc:creator>Kesava Suriyan.P</dc:creator>
  <dc:creator>Baranilingesan.</dc:creator>
  <dc:date>2020-08-30</dc:date>
  <dc:description>This paper proposes the automatic switching of a three-phase induction motor to provide an uninterrupted motor operation in industrial applications. To accomplish this aim, two motors are employed one is a primary motor and another one is a back-up machine that is automatically made switched on in the case of primary motor fails to operate. All the process is controlled by the Arduino controller design. Moreover, the continuous running of motors causes the motor temperature to rise, which is effectively handled by the proposed controller design, which automatically switches the primary and backup motor for every 24 hours. The motor operating status is automatically updated by means of GSM strategy to the operator. Here arduino controller used to control the induction motor with the help of relay. In the case of unexpected fault conditions, to protect the system both the motors are automatically switched off and a message is passed to the operator about the fault condition. The proposed methodology is experimentally validated by a hardware model with better working performance.</dc:description>
  <dc:identifier>https://zenodo.org/record/5543592</dc:identifier>
  <dc:identifier>10.35940/ijeat.F1580.089620</dc:identifier>
  <dc:identifier>oai:zenodo.org:5543592</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>issn:2249-8958</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/legalcode</dc:rights>
  <dc:source>International Journal of Engineering and Advanced Technology (IJEAT) 9(6) 460-463</dc:source>
  <dc:subject>Arduino Controller, Automation, GSM, Three-phase Induction motor</dc:subject>
  <dc:subject>ISSN</dc:subject>
  <dc:subject>Retrieval Number</dc:subject>
  <dc:title>Automatic Switching of Three Phase Induction  Motor during Fault Condition</dc:title>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:type>publication-article</dc:type>
</oai_dc:dc>
50
27
views
downloads
Views 50
Downloads 27
Data volume 12.1 MB
Unique views 50
Unique downloads 27

Share

Cite as