Preprint Open Access

Calibration System for DC Power/Energy Measurement chain in Railway applications

Crotti Gabriella; Delle Femine Antonio; Gallo Daniele; Giordano Domenico; Luiso Mario; Landi Carmine; Signorino Davide


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Combined Transducers</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Power Measurement</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Phantom Power</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">DC Railway</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Energy Meter</subfield>
  </datafield>
  <controlfield tag="005">20210302002713.0</controlfield>
  <controlfield tag="001">4569831</controlfield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="d">24-28 August 2020</subfield>
    <subfield code="g">CPEM</subfield>
    <subfield code="a">Conference on Precision Electromagnetic Measurements</subfield>
    <subfield code="c">Denver, CO, USA</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Università degli Studi della Campania: Luigi Vanvitelli</subfield>
    <subfield code="0">(orcid)0000-0002-2503-8772</subfield>
    <subfield code="a">Delle Femine Antonio</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Università degli Studi della Campania: Luigi Vanvitelli</subfield>
    <subfield code="0">(orcid)0000-0002-1553-7498</subfield>
    <subfield code="a">Gallo Daniele</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">INRIM</subfield>
    <subfield code="0">(orcid)0000-0002-2616-9459</subfield>
    <subfield code="a">Giordano Domenico</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Università degli Studi della Campania: Luigi Vanvitelli</subfield>
    <subfield code="0">(orcid)0000-0003-1311-9791</subfield>
    <subfield code="a">Luiso Mario</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Università degli Studi della Campania: Luigi Vanvitelli</subfield>
    <subfield code="0">(orcid)0000-0003-0922-883X</subfield>
    <subfield code="a">Landi Carmine</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Politecnico di Torino, Inrim</subfield>
    <subfield code="0">(orcid)0000-0001-5141-6768</subfield>
    <subfield code="a">Signorino Davide</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">368741</subfield>
    <subfield code="z">md5:8556154ab0fc173e5d15ac63e79a414f</subfield>
    <subfield code="u">https://zenodo.org/record/4569831/files/Calibration System for DC PowerEnergy Measurement chain in Railway applications .pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2020-09-10</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="p">user-inrim</subfield>
    <subfield code="o">oai:zenodo.org:4569831</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">INRIM</subfield>
    <subfield code="0">(orcid)0000-0001-7563-396X</subfield>
    <subfield code="a">Crotti Gabriella</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Calibration System for DC Power/Energy Measurement chain in Railway applications</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-inrim</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;In order to guarantee the European interoperability of rolling stock, the European Union (EU) established that all the trains shall be equipped with an Energy Measurement Function (EMF) for billing purposes. The measurement accuracy of such devices should be assessed and periodically re-verified, as required by EN 50462-2. This paper describes a setup for the calibration of combined voltage and current transducers and EMFs for on-board Direct Current (DC) train installation. The reference system is able to generate an arbitrary DC phantom power up to 6 MW with voltage up to 5 kV and a current up to 1.2 kA. Furthermore, in order to perform tests as close as possible to real operating conditions, the system allows performing dynamical tests, reproducing waveforms obtained in real measurement campaigns. The computed uncertainty for steady state tests is 0.025 %, whereas the target uncertainty for dynamic tests is 0.1%. The generation system can also be applied for on-board reverification of EMF&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1109/CPEM49742.2020.9191718</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">preprint</subfield>
  </datafield>
</record>
28
52
views
downloads
Views 28
Downloads 52
Data volume 19.2 MB
Unique views 25
Unique downloads 52

Share

Cite as