  "description": "<p>Abstract:</p>\n\n<p>Background: Gait impairments in Parkinson&rsquo;s disease (PD) are quantified using inertial sensors under standardized test settings in the hospital. Recent studies focused on the assessment of free-living gait in PD. However, the clinical relevance of standardized gait tests recorded at the patient&rsquo;s home is unclear. Objective: To evaluate the reliability of supervised, standardized sensor-based gait outcomes at home compared to the hospital. Methods: Patients with PD (n=20) were rated by a trained investigator using the Unified Parkinson Disease Rating Scale (UPDRS-III). Gait tests included a standardized 4x10 m walk test and the Timed Up and Go Test (TUG). Tests were performed in the hospital (HOSPITAL) and at patients&rsquo; home (HOME), and controlled for investigator, time of the day, and medication. Statistics included reliability analysis using Intra-Class correlations and Bland-Altman plots. Results: UPDRS-III and TUG were comparable between HOSPITAL and HOME. PD patients&rsquo; gait at HOME was slower (gait velocity &Delta;=-0.07&plusmn;0.11 m/s,-6.1 %), strides were shorter (stride length &Delta;=-9.2&plusmn;9.4 cm;-7.3 %), and shuffling of gait was more present (maximum toe-clearance &Delta;=-0.7&plusmn;2.5 cm;-8.8 %). Particularly, narrow walkways (&lt; 85 cm) resulted in a significant reduction of gait velocity at home. Reliability analysis (HOSPITAL vs. HOME) revealed excellent ICC coefficients for UPDRS-III (0.950, p&lt;0.000) and gait parameters (e.g. stride length: 0.898,p&lt;0.000; gait velocity: 0.914,p&lt;0.000; stance time: 0.922,p&lt;0.000; stride time: 0.907,p&lt;0.000). Conclusions: This pilot study underlined the clinical relevance of gait parameters by showing excellent reliability for supervised, standardized gait tests at HOSPITAL and HOME, even though gait parameters were different between test conditions.</p>\n\n<p>This work was supported by the Mobilise-D project, that has received funding from the Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No. 820820. This Joint Undertaking receives support from the European Union&#39;s Horizon 2020 research and innovation program and the European Federation of Pharmaceutical Industries and Associations (EFPIA). Content in this publication reflects the authors&rsquo; view and neither IMI nor the European Union, EFPIA, or any Associated Partners are responsible for any use that may be made of the information contained herein.</p>", 
  "license": "https://creativecommons.org/licenses/by/4.0/legalcode", 
  "creator": [
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Ga\u00dfner, H."
    }, 
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Sanders, P."
    }, 
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Dietrich, A."
    }, 
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Marxreiter, F."
    }, 
    {
      "affiliation": "Machine Learning and Data Analytics Lab, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Eskofier, B."
    }, 
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany", 
      "@type": "Person", 
      "name": "Winkler, J."
    }, 
    {
      "affiliation": "Department of Molecular Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-N\u00fcrnberg (FAU), Erlangen, Germany. Medical Valley \u2013 Digital Health Application Center GmbH, Bamberg, Germany. Fraunhofer Institute for Integrated Circuits IIS, Erlangen, Germany", 
      "@type": "Person", 
      "name": "Klucken, J."
    }
  ], 
  "headline": "Clinical relevance of standardized mobile gait tests - reliability analysis between gait recordings at hospital and home in Parkinson's disease: A pilot study", 
  "image": "https://zenodo.org/static/img/logos/zenodo-gradient-round.svg", 
  "datePublished": "2020-10-27", 
  "url": "https://zenodo.org/record/4468815", 
  "keywords": [
    "Parkinson's disease", 
    "Gait analysis", 
    "Wearable sensors", 
    "Telemedicine", 
    "Home Monitoring"
  ], 
  "@context": "https://schema.org/", 
  "identifier": "https://doi.org/10.5281/zenodo.4468815", 
  "@id": "https://doi.org/10.5281/zenodo.4468815", 
  "@type": "ScholarlyArticle", 
  "name": "Clinical relevance of standardized mobile gait tests - reliability analysis between gait recordings at hospital and home in Parkinson's disease: A pilot study"
}
179
92
views
downloads
All versions This version
Views 179179
Downloads 9292
Data volume 209.9 MB209.9 MB
Unique views 153153
Unique downloads 9090

Share

Cite as