Dataset Restricted Access

Aging Test - Pouch Cell - Modules - Part 01 (Module 3)

Juarez Robles, Daniel; Jeevarajan, Judith A.; Mukherjee, Partha P.

Test Sample Specifications

  • Configuration: 5P5S (5 cells in parallel (bank), 5 banks in series) Module
  • Nominal Capacity = 16.5 Ah
  • Graphite / NCA Cells
  • Pouch Cells 

Cycling Protocol

  • Charge: CCCV at C/2 up to 21.0 V and a C/100 cutoff current 
  • Discharge: CC at C/2 down to 13.5 V

Cycling Life

  • Number of Cycles = 2000
  • Capacity Fade = 20.00 %
Restricted Access

You may request access to the files in this upload, provided that you fulfil the conditions below. The decision whether to grant/deny access is solely under the responsibility of the record owner.


To access the files, send an email to NFP.BatterySafety@ul.org