Test Sample Specifications

  • Nominal Capacity = 3300 mAh
  • Graphite / NCA 
  • Pouch Cell 

Cycling Protocol

  • Charge: CCCV at 1C up to 4.2 V and a C/20 cutoff current 
  • Discharge: CC at 1C down to 2.7 V

Cycling Life

  • Number of Cycles = 3080
  • Aimed Capacity Fade = 20.00 %
  • Actual Capacity Fade = 20.17 %
File 7 is not included as it was corrupted due to a power outage.