Dataset Open Access
Wang, Xiaoqing;
Tan, Zhengguo;
Scholand, Nick;
Roeloffs, Volkert;
Uecker, Martin
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="DOI">10.5281/zenodo.4381986</identifier> <creators> <creator> <creatorName>Wang, Xiaoqing</creatorName> <givenName>Xiaoqing</givenName> <familyName>Wang</familyName> <affiliation>University Medical Center Göttingen</affiliation> </creator> <creator> <creatorName>Tan, Zhengguo</creatorName> <givenName>Zhengguo</givenName> <familyName>Tan</familyName> <affiliation>University Medical Center Göttingen</affiliation> </creator> <creator> <creatorName>Scholand, Nick</creatorName> <givenName>Nick</givenName> <familyName>Scholand</familyName> <affiliation>University Medical Center Göttingen</affiliation> </creator> <creator> <creatorName>Roeloffs, Volkert</creatorName> <givenName>Volkert</givenName> <familyName>Roeloffs</familyName> <affiliation>University Medical Center Göttingen</affiliation> </creator> <creator> <creatorName>Uecker, Martin</creatorName> <givenName>Martin</givenName> <familyName>Uecker</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-8850-809X</nameIdentifier> <affiliation>University Medical Center Göttingen</affiliation> </creator> </creators> <titles> <title>Data for: Physics-based Reconstruction Methods for Magnetic Resonance Imaging</title> </titles> <publisher>Zenodo</publisher> <publicationYear>2020</publicationYear> <subjects> <subject>magnetic resonance imaging</subject> <subject>computational imaging</subject> </subjects> <dates> <date dateType="Issued">2020-12-21</date> </dates> <resourceType resourceTypeGeneral="Dataset"/> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/4381986</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsSupplementTo" resourceTypeGeneral="JournalArticle">10.1098/rsta.2020.0196</relatedIdentifier> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.4060286</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://zenodo.org/communities/compmri</relatedIdentifier> </relatedIdentifiers> <version>2</version> <rightsList> <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract"><p>Magnetic Resonance Imaging&nbsp;measurement data used in our paper about &#39;Physics-based Reconstruction Methods for Magnetic Resonance Imaging&#39; (DOI: 10.1098/rsta.2020.0196). (In&nbsp;version 2 the IR-FLASH data set was replaced with one which is from&nbsp;the same volunteer and slice as the ME-SE data set.)&nbsp;</p> <p>The data is acquired from healthy volunteers and stored in the format of the BART toolbox&nbsp;(DOI:&nbsp;<a href="http://doi.org/10.5281/zenodo.592960">10.5281/zenodo.592960</a>).</p> <p>The acquisition parameters are shown in the following table:</p> <p>flip angle[◦]&nbsp;TR/TE/ Delta TE[ms] bandwidth [Hz/px] matrix spokes TA[s] FOV[mm] slice[mm]</p> <p>IR-FLASH 6 4.10/2.58 630 256 &times; 256 1020 4 192 5<br> ME-SE 90/180 2500/9.9/9.9 390 256 &times; 256 25 &times; 16 80 192 3<br> ME-FLASH 5 10.60/1.37/1.34 960 200&times; 200 33 &times; 7 0.35a 320 5<br> PC-FLASH 10 4.46/2.96 1250 210 &times; 210 2 &times; 7 15 320 5<br> fmSSFPb 15 4.5/2.25 840 192&times; 192 4 &times; 101 &times; 40 137 192 1</p></description> </descriptions> </resource>
All versions | This version | |
---|---|---|
Views | 256 | 190 |
Downloads | 1,756 | 768 |
Data volume | 120.0 GB | 66.4 GB |
Unique views | 201 | 161 |
Unique downloads | 503 | 150 |