Dataset Open Access

Estimating TOF from ultrasound signal over bare steel sample of 5 mm thickness

Ainhoa Cortes; Andoni Irizar


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nmm##2200000uu#4500</leader>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">ultrasound; corrosion; bare steel; loss of thickness; piezoelectric</subfield>
  </datafield>
  <controlfield tag="005">20201120002708.0</controlfield>
  <controlfield tag="001">4280715</controlfield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">CEIT</subfield>
    <subfield code="a">Andoni Irizar</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">55958</subfield>
    <subfield code="z">md5:8262339d6553ef54f0380803ef8a093c</subfield>
    <subfield code="u">https://zenodo.org/record/4280715/files/S355-00-02-YS15-10_echoN_2_20200616130623_nxc_TOF.csv</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">123293</subfield>
    <subfield code="z">md5:87525e6b775abeb65ed7686f46d4825c</subfield>
    <subfield code="u">https://zenodo.org/record/4280715/files/S355-00-02_YS15-10_echoN_2_20200616130623_nxc_TOF.json</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2020-10-31</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire_data</subfield>
    <subfield code="o">oai:zenodo.org:4280715</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">CEIT</subfield>
    <subfield code="0">(orcid)0000-0002-9258-129X</subfield>
    <subfield code="a">Ainhoa Cortes</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Estimating TOF from ultrasound signal over bare steel sample of 5 mm thickness</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;These data have been obtained using the CEIT ultrasound testbed exciting a PZT piezoelectric sensor with a +/-15 volts pulse located over a 5 mm bare steel sample. The testbed receives the ultrasound response and estimates the TOF measuring the distance between two consecutive echoes. The aim is to develop an embedded system to measure the loss of thickness produced by corrosion.&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="n">doi</subfield>
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.5281/zenodo.4165575</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.5281/zenodo.4280715</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">dataset</subfield>
  </datafield>
</record>
229
101
views
downloads
All versions This version
Views 229127
Downloads 10182
Data volume 7.2 MB4.9 MB
Unique views 159114
Unique downloads 8875

Share

Cite as