Dataset Open Access

Estimating TOF from ultrasound signal over bare steel sample of 5 mm thickness

Ainhoa Cortes; Andoni Irizar


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="DOI">10.5281/zenodo.4280715</identifier>
  <creators>
    <creator>
      <creatorName>Ainhoa Cortes</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-9258-129X</nameIdentifier>
      <affiliation>CEIT</affiliation>
    </creator>
    <creator>
      <creatorName>Andoni Irizar</creatorName>
      <affiliation>CEIT</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Estimating TOF from ultrasound signal over bare steel sample of 5 mm thickness</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2020</publicationYear>
  <subjects>
    <subject>ultrasound; corrosion; bare steel; loss of thickness; piezoelectric</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2020-10-31</date>
  </dates>
  <resourceType resourceTypeGeneral="Dataset"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/4280715</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.4165575</relatedIdentifier>
  </relatedIdentifiers>
  <version>0.0</version>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;These data have been obtained using the CEIT ultrasound testbed exciting a PZT piezoelectric sensor with a +/-15 volts pulse located over a 5 mm bare steel sample. The testbed receives the ultrasound response and estimates the TOF measuring the distance between two consecutive echoes. The aim is to develop an embedded system to measure the loss of thickness produced by corrosion.&lt;/p&gt;</description>
  </descriptions>
</resource>
229
101
views
downloads
All versions This version
Views 229127
Downloads 10182
Data volume 7.2 MB4.9 MB
Unique views 159114
Unique downloads 8875

Share

Cite as