Conference paper Open Access

Određivanje ulaznih podataka za proračun prenosnih kapaciteta

Tasić, Andrej; Đalović, Andrijana


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">srp</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">NTC</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">critical network element</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">CNEC</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">sensitivity analysis</subfield>
  </datafield>
  <controlfield tag="005">20201008002654.0</controlfield>
  <controlfield tag="001">4068287</controlfield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="d">20-23 October 2020</subfield>
    <subfield code="p">12</subfield>
    <subfield code="a">19th Session of CIGRE Serbia</subfield>
    <subfield code="c">on-line</subfield>
    <subfield code="n">C2</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Security Coordination Centre SCC Ltd. Belgrade</subfield>
    <subfield code="a">Đalović, Andrijana</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">521744</subfield>
    <subfield code="z">md5:6707fcc77cc8424b4288d0230c91ac91</subfield>
    <subfield code="u">https://zenodo.org/record/4068287/files/Odredivanje ulaznih podataka za proracun prenosnih kapaciteta.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="y">Conference website</subfield>
    <subfield code="u">http://www.cigresrbija.rs/19simpozijum.html</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2020-10-21</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="o">oai:zenodo.org:4068287</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Security Coordination Centre SCC Ltd. Belgrade</subfield>
    <subfield code="a">Tasić, Andrej</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Određivanje ulaznih podataka za proračun prenosnih kapaciteta</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">773430</subfield>
    <subfield code="a">CROSS BOrder management of variable renewable energies and storage units enabling a transnational Wholesale market</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;DETERMINATION OF CAPACITY CALCULATION INPUT DATA&lt;/p&gt;

&lt;p&gt;Abstract &amp;mdash; With the initiative of Energy Community, and in cooperation of majority of SEE TSOs and several regulators, the initial methodology for coordinated capacity calculation in SEE region has been defined. This methodology is a starting point for further business process development. In accordance with already applied practice, NTC approach is adopted, and one of preconditions for coordinated capacity calculation is determination of input data in the view of Critical Network Element and Contingency (CNEC) pairs and Remedial actions.&lt;br&gt;
CNEC pair is composed from two network element: Critical Network Element &amp;ndash; CNE, whose loading is monitored during the calculation, and Contingency whose outage is simulated during the calculation. Network element, cross-border or within one control area, whose sensitivity on the transaction between two control areas is greater than defined sensitivity threshold, will be considered as CNE. Network element for whose outage sensitivity of CNE is greater than defined sensitivity threshold, will be paired with the given CNE and in that way one CNEC pair will be created. CNEC pairs determined in this way represents one input data for coordinated cross-border capacity calculation.&lt;br&gt;
The aim of the paper is to propose a methodology for determination of CNEC pairs, as input data for NTC calculation in SEE region. Results of CNEC pairs determination for NTC borders of three TSOs will be presented.&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="n">doi</subfield>
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.5281/zenodo.4068286</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.5281/zenodo.4068287</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
</record>
59
79
views
downloads
All versions This version
Views 5959
Downloads 7979
Data volume 41.2 MB41.2 MB
Unique views 5353
Unique downloads 7676

Share

Cite as