Journal article Open Access

Measuring Cable Sheath Currents to Detect Defects in Cable Sheath Connections

Marina Adel


JSON Export

{
  "files": [
    {
      "links": {
        "self": "https://zenodo.org/api/files/0d527190-b159-4540-8937-2ab07ae79781/Upec%202017-fgv-10-fgv%2013%20julio.docx"
      }, 
      "checksum": "md5:f6821309ef06c28c76ce9e1fd1913172", 
      "bucket": "0d527190-b159-4540-8937-2ab07ae79781", 
      "key": "Upec 2017-fgv-10-fgv 13 julio.docx", 
      "type": "docx", 
      "size": 496308
    }
  ], 
  "owners": [
    54781
  ], 
  "doi": "10.5281/zenodo.3871559", 
  "stats": {
    "version_unique_downloads": 2.0, 
    "unique_views": 10.0, 
    "views": 14.0, 
    "version_views": 14.0, 
    "unique_downloads": 2.0, 
    "version_unique_views": 10.0, 
    "volume": 992616.0, 
    "version_downloads": 2.0, 
    "downloads": 2.0, 
    "version_volume": 992616.0
  }, 
  "links": {
    "doi": "https://doi.org/10.5281/zenodo.3871559", 
    "conceptdoi": "https://doi.org/10.5281/zenodo.3871558", 
    "bucket": "https://zenodo.org/api/files/0d527190-b159-4540-8937-2ab07ae79781", 
    "conceptbadge": "https://zenodo.org/badge/doi/10.5281/zenodo.3871558.svg", 
    "html": "https://zenodo.org/record/3871559", 
    "latest_html": "https://zenodo.org/record/3871559", 
    "badge": "https://zenodo.org/badge/doi/10.5281/zenodo.3871559.svg", 
    "latest": "https://zenodo.org/api/records/3871559"
  }, 
  "conceptdoi": "10.5281/zenodo.3871558", 
  "created": "2020-06-01T10:48:32.139953+00:00", 
  "updated": "2020-06-01T22:18:20.212262+00:00", 
  "conceptrecid": "3871558", 
  "revision": 2, 
  "id": 3871559, 
  "metadata": {
    "access_right_category": "success", 
    "doi": "10.5281/zenodo.3871559", 
    "description": "<p>This paper presents a method for detecting different types of defects in the cable sheaths interconnected in a cross bonding configuration of a HV cable system installed in flat or trefoil layout using the sheath currents as input data. Three different defects have been analyzed: electric continuity loss of earth connection, short-circuit between sectionalized metal sheaths of a cable joint and link-box flooding. The sheath current has been calculated by two different approaches, one on the basis of theoretical equations, programed in MATLAB&reg; and the other on the basis of ATP software simulating the cable system model. The results obtained using both methods have achieved a good agreement between them. A simple criterion by the means of a easy normalized code of four discrete levels 0, 1, 2 and 3 has been developed to distinguish the magnitude level of change of sheath currents in case of the indicated defect existence in&nbsp; order to trigger alarm.</p>", 
    "language": "eng", 
    "title": "Measuring Cable Sheath Currents to Detect Defects in Cable Sheath Connections", 
    "license": {
      "id": "CC-BY-4.0"
    }, 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "3871558"
          }, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "3871559"
          }
        }
      ]
    }, 
    "grants": [
      {
        "code": "676042", 
        "links": {
          "self": "https://zenodo.org/api/grants/10.13039/501100000780::676042"
        }, 
        "title": "Metrology Excellence Academic Network for Smart Grids", 
        "acronym": "MEAN4SG", 
        "program": "H2020", 
        "funder": {
          "doi": "10.13039/501100000780", 
          "acronyms": [], 
          "name": "European Commission", 
          "links": {
            "self": "https://zenodo.org/api/funders/10.13039/501100000780"
          }
        }
      }
    ], 
    "keywords": [
      "Hv. Cable; Sheath current, Earth disconnection; ATP software; defect detection in sheaths; earth disconnection; short-circuit in cable joints, link-box flooding; defect alarm"
    ], 
    "publication_date": "2020-06-01", 
    "creators": [
      {
        "affiliation": "FFII", 
        "name": "Marina Adel"
      }
    ], 
    "access_right": "open", 
    "resource_type": {
      "subtype": "article", 
      "type": "publication", 
      "title": "Journal article"
    }, 
    "related_identifiers": [
      {
        "scheme": "doi", 
        "identifier": "10.5281/zenodo.3871558", 
        "relation": "isVersionOf"
      }
    ]
  }
}
14
2
views
downloads
All versions This version
Views 1414
Downloads 22
Data volume 992.6 kB992.6 kB
Unique views 1010
Unique downloads 22

Share

Cite as