Preprint Open Access

Practical measurements of partial discharges in a smart grid laboratory

Barrios, Sonia; Gilbert, Ian; Hurtado, Aritz; Mulroy, Patrick; Orue, Iñaki


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="a">2020-05-31</subfield>
  </datafield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Partial discharges</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Switchgear</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Power cables</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Partial discharge measurement</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Attenuation measurement</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Smart grids</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Energy measurement</subfield>
  </datafield>
  <controlfield tag="005">20200531101820.0</controlfield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">© 2018 IEEE.  Personal use of this material is permitted.  Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.</subfield>
  </datafield>
  <controlfield tag="001">3856419</controlfield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Ormazabal Corporate Technology</subfield>
    <subfield code="0">(orcid)0000-0002-6343-4936</subfield>
    <subfield code="a">Gilbert, Ian</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Ormazabal Corporate Technology</subfield>
    <subfield code="a">Hurtado, Aritz</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Ormazabal Corporate Technology</subfield>
    <subfield code="a">Mulroy, Patrick</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Ormazabal Corporate Technology</subfield>
    <subfield code="a">Orue, Iñaki</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">1279170</subfield>
    <subfield code="z">md5:4c07d5dfcff0040c79192baaa312a99e</subfield>
    <subfield code="u">https://zenodo.org/record/3856419/files/Smagrimet18_final.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2018-05-31</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="p">user-oct-cit</subfield>
    <subfield code="o">oai:zenodo.org:3856419</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Ormazabal Corporate Technology</subfield>
    <subfield code="a">Barrios, Sonia</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Practical measurements of partial discharges in a smart grid laboratory</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-oct-cit</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">676042</subfield>
    <subfield code="a">Metrology Excellence Academic Network for Smart Grids</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;On-line measurement and monitoring of partial discharges in an MV cable system, including terminations and joints, is a challenging subject because it interacts with other components of the distribution network such as ring main units. The stochastic nature of partial discharges, the different configurations of the network, the external noise and the lack of standard recommendations have consequentially made the quantification of this phenomena more difficult. This paper is an attempt to investigate the behaviour of a theoretical pulse propagation and a real partial discharge in different circuits with almost the same configuration, that can be easily configured in a real Smart Grid laboratory. Several experiments and measurements were performed in order to compare these circuits and to find a factor that represents the influence of different circuit components to use as a reference or calibration to ensure the validity of further measurements.&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.23919/SMAGRIMET.2018.8369824</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">preprint</subfield>
  </datafield>
</record>
16
7
views
downloads
Views 16
Downloads 7
Data volume 9.0 MB
Unique views 12
Unique downloads 5

Share

Cite as