Preprint Open Access

Practical measurements of partial discharges in a smart grid laboratory

Barrios, Sonia; Gilbert, Ian; Hurtado, Aritz; Mulroy, Patrick; Orue, Iñaki


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://zenodo.org/record/3856419</identifier>
  <creators>
    <creator>
      <creatorName>Barrios, Sonia</creatorName>
      <givenName>Sonia</givenName>
      <familyName>Barrios</familyName>
      <affiliation>Ormazabal Corporate Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Gilbert, Ian</creatorName>
      <givenName>Ian</givenName>
      <familyName>Gilbert</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6343-4936</nameIdentifier>
      <affiliation>Ormazabal Corporate Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Hurtado, Aritz</creatorName>
      <givenName>Aritz</givenName>
      <familyName>Hurtado</familyName>
      <affiliation>Ormazabal Corporate Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Mulroy, Patrick</creatorName>
      <givenName>Patrick</givenName>
      <familyName>Mulroy</familyName>
      <affiliation>Ormazabal Corporate Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Orue, Iñaki</creatorName>
      <givenName>Iñaki</givenName>
      <familyName>Orue</familyName>
      <affiliation>Ormazabal Corporate Technology</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Practical measurements of partial discharges in a smart grid laboratory</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2018</publicationYear>
  <subjects>
    <subject>Partial discharges</subject>
    <subject>Switchgear</subject>
    <subject>Power cables</subject>
    <subject>Partial discharge measurement</subject>
    <subject>Attenuation measurement</subject>
    <subject>Smart grids</subject>
    <subject>Energy measurement</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2018-05-31</date>
  </dates>
  <language>en</language>
  <resourceType resourceTypeGeneral="Text">Preprint</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/3856419</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.23919/SMAGRIMET.2018.8369824</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://zenodo.org/communities/oct-cit</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;On-line measurement and monitoring of partial discharges in an MV cable system, including terminations and joints, is a challenging subject because it interacts with other components of the distribution network such as ring main units. The stochastic nature of partial discharges, the different configurations of the network, the external noise and the lack of standard recommendations have consequentially made the quantification of this phenomena more difficult. This paper is an attempt to investigate the behaviour of a theoretical pulse propagation and a real partial discharge in different circuits with almost the same configuration, that can be easily configured in a real Smart Grid laboratory. Several experiments and measurements were performed in order to compare these circuits and to find a factor that represents the influence of different circuit components to use as a reference or calibration to ensure the validity of further measurements.&lt;/p&gt;</description>
    <description descriptionType="Other">© 2018 IEEE.  Personal use of this material is permitted.  Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.</description>
  </descriptions>
  <fundingReferences>
    <fundingReference>
      <funderName>European Commission</funderName>
      <funderIdentifier funderIdentifierType="Crossref Funder ID">10.13039/501100000780</funderIdentifier>
      <awardNumber awardURI="info:eu-repo/grantAgreement/EC/H2020/676042/">676042</awardNumber>
      <awardTitle>Metrology Excellence Academic Network for Smart Grids</awardTitle>
    </fundingReference>
  </fundingReferences>
</resource>
16
7
views
downloads
Views 16
Downloads 7
Data volume 9.0 MB
Unique views 12
Unique downloads 5

Share

Cite as