3689756
doi
10.5281/zenodo.3689756
oai:zenodo.org:3689756
user-epfl
Lignos Dimitrios G.
Associate Professor at EPFL
Inelastic panel zone database
Skiadopoulos Andronikos
Doctoral Assistant at EPFL
info:eu-repo/semantics/openAccess
Creative Commons Attribution 2.0 Generic
https://creativecommons.org/licenses/by/2.0/legalcode
steel moment resisting frames
beam-to-column connections
inelastic panel zones
structural performance databases
continuum finite element modeling
<p>1. <a href="https://zenodo.org/api/files/ab969b9b-667b-47f2-aa2e-24e2ffa53d5d/Inelastic_Panel_Zone_Database_v1.xlsx?versionId=3bedad71-6f00-45e0-bc1a-92d2bcd9205a">Inelastic_Panel_Zone_Database_v1.xlsx</a></p>
<p>An inelastic panel zone database of fully restrained beam-to-column connection tests as part of steel moment-resisting frames (MRFs) is provided. The database consists of 100 tests of experimental research over the last 50 years. The collection and metadata methodology are thoroughly presented in Skiadopoulos and Lignos (2020).</p>
<p>2. <a href="https://zenodo.org/api/files/ab969b9b-667b-47f2-aa2e-24e2ffa53d5d/Digitized_Data_v1.7z?versionId=59e73621-fb18-414e-997e-ea0231934ddc">Digitized_Data_v1.7z</a></p>
<p>Full digitized histories of the local panel zone shear force - shear distortion as well as the global force - story drift ratio hysteretic diagrams of each experiment are provided. A MATLAB code to plot and acquire the performance parameters of interest is shared.</p>
<p>3. <a href="https://zenodo.org/api/files/ab969b9b-667b-47f2-aa2e-24e2ffa53d5d/Panel_Zone_Deduced_Parameters_v1.m?versionId=90f42cf6-7573-40dc-b382-a1233cb8162c">Panel_Zone_Deduced_Parameters_v1.m</a></p>
<p>A MATLAB code to automatically deduce the measured panel zone response parameters of interest is shared.</p>
<p>4. <a href="https://zenodo.org/api/files/ab969b9b-667b-47f2-aa2e-24e2ffa53d5d/ABAQUS_Model_Validation_v1.7z?versionId=967b955d-b115-4194-b769-ea66d4385fcf">ABAQUS_Model_Validation_v1.7z</a></p>
<p>The provided hysteretic responses are exploited for continuum finite element (CFE) model validation. Such a validated CFE model is shared (.inp) together with the respective buckling analysis files (.inp and .fil). The model represents SPEC-6 by Ricles et al. (2004) and was generated by ABAQUS.</p>
Disclaimer:
The inelastic panel zone database and aforementioned information was assembled as a service to the research and practice communities in earthquake/structural engineering. EPFL, Nippon Steel Corporation, and the researchers who performed the experiments make no warranties to the accuracy of the information that has been collected, digitized and processed. If you have any questions, comments or suggestions, please contact Prof. Dimitrios Lignos at EPFL.
Zenodo
2020-02-27
info:eu-repo/semantics/other
3689755
user-epfl
v1
1610026178.640548
81191399
md5:268b8c6199c914bacd8aeaec8b40c2a9
https://zenodo.org/records/3689756/files/ABAQUS_Model_Validation_v1.7z
5212783
md5:dfcf41a927c6c4797d52418629eccb4e
https://zenodo.org/records/3689756/files/Digitized_Data_v1.7z
2378125
md5:7591b38e751c86cfa8bd8d30aa43d83d
https://zenodo.org/records/3689756/files/Inelastic_Panel_Zone_Database_v1.xlsx
7842
md5:0715dc758d6b27b94409ed3e7c6bb66a
https://zenodo.org/records/3689756/files/Panel_Zone_Deduced_Parameters_v1.m
public
10.5281/zenodo.3689755
isVersionOf
doi