Conference paper Open Access

Modelling of Output Admittance Coupling Between Shunt Active Power Filters and Non-linear Loads

Jintao Lei; Zian Qin; Wuhua Li; Pavol Bauer; Xiangning He


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">SAPF</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">system stability</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">modelling</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">output admittance coupling</subfield>
  </datafield>
  <controlfield tag="005">20200120144936.0</controlfield>
  <controlfield tag="001">3585719</controlfield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="d">11-14 Nov 2019</subfield>
    <subfield code="g">eGrid 2019</subfield>
    <subfield code="a">4th IEEE Workshop on the Electronic Grid</subfield>
    <subfield code="c">Xiamen, China</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Delft University of Technology</subfield>
    <subfield code="a">Zian Qin</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Zhejiang University</subfield>
    <subfield code="a">Wuhua Li</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Delft University of Technology</subfield>
    <subfield code="a">Pavol Bauer</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Zhejiang University</subfield>
    <subfield code="a">Xiangning He</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">1127074</subfield>
    <subfield code="z">md5:16e32fc48c5b226db9f30e1cfb377481</subfield>
    <subfield code="u">https://zenodo.org/record/3585719/files/Modelling+of+Output+Admittance+Coupling+Between+Shunt+Active+Power+Filters+and+Non-linear+Loads-Full+Paper-FinalVersion.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="y">Conference website</subfield>
    <subfield code="u">http://www.ieee-egrid.org/</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2019-11-11</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="p">user-rdc2mt</subfield>
    <subfield code="o">oai:zenodo.org:3585719</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Zhejiang University</subfield>
    <subfield code="a">Jintao Lei</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Modelling of Output Admittance Coupling Between Shunt Active Power Filters and Non-linear Loads</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-rdc2mt</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">734796</subfield>
    <subfield code="a">Research, Demonstration, and Commercialisation of DC Microgrid Technologies</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
    <subfield code="a">Creative Commons Attribution 4.0 International</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;Nowadays Shunt Active Power Filter (SAPF) system still suffers from stability issue which heavily detect its performance. In this paper, an improved system level model is proposed to investigate the coupling effect that will cause the system level instability. This model describes the coupling effect with an additional output admittance and shows system stability more directly. In order to investigate the correctness of the proposed method, a grid including the SAPF and a non-linear load is modelled with both conventional approach and proposed modeling method. Simulations are carried out with the same parameters. Results show that the instability of the grid current observed in the simulation results is not reflected in the stability analysis based on the conventional model. On the other hand, the stability analysis with the new model matches the simulation results very well. Also, further verification is made by a frequency-sweep result, which proves the accuracy of proposed model.&lt;/p&gt;</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="n">doi</subfield>
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.5281/zenodo.3585718</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.5281/zenodo.3585719</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
</record>
59
103
views
downloads
All versions This version
Views 5959
Downloads 103103
Data volume 116.1 MB116.1 MB
Unique views 5252
Unique downloads 101101

Share

Cite as