Conference paper Open Access

Modelling of Output Admittance Coupling Between Shunt Active Power Filters and Non-linear Loads

Jintao Lei; Zian Qin; Wuhua Li; Pavol Bauer; Xiangning He


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="DOI">10.5281/zenodo.3585719</identifier>
  <creators>
    <creator>
      <creatorName>Jintao Lei</creatorName>
      <affiliation>Zhejiang University</affiliation>
    </creator>
    <creator>
      <creatorName>Zian Qin</creatorName>
      <affiliation>Delft University of Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Wuhua Li</creatorName>
      <affiliation>Zhejiang University</affiliation>
    </creator>
    <creator>
      <creatorName>Pavol Bauer</creatorName>
      <affiliation>Delft University of Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Xiangning He</creatorName>
      <affiliation>Zhejiang University</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Modelling of Output Admittance Coupling Between Shunt Active Power Filters and Non-linear Loads</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2019</publicationYear>
  <subjects>
    <subject>SAPF</subject>
    <subject>system stability</subject>
    <subject>modelling</subject>
    <subject>output admittance coupling</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2019-11-11</date>
  </dates>
  <language>en</language>
  <resourceType resourceTypeGeneral="ConferencePaper"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/3585719</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.3585718</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://zenodo.org/communities/rdc2mt</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;Nowadays Shunt Active Power Filter (SAPF) system still suffers from stability issue which heavily detect its performance. In this paper, an improved system level model is proposed to investigate the coupling effect that will cause the system level instability. This model describes the coupling effect with an additional output admittance and shows system stability more directly. In order to investigate the correctness of the proposed method, a grid including the SAPF and a non-linear load is modelled with both conventional approach and proposed modeling method. Simulations are carried out with the same parameters. Results show that the instability of the grid current observed in the simulation results is not reflected in the stability analysis based on the conventional model. On the other hand, the stability analysis with the new model matches the simulation results very well. Also, further verification is made by a frequency-sweep result, which proves the accuracy of proposed model.&lt;/p&gt;</description>
  </descriptions>
  <fundingReferences>
    <fundingReference>
      <funderName>European Commission</funderName>
      <funderIdentifier funderIdentifierType="Crossref Funder ID">10.13039/100010661</funderIdentifier>
      <awardNumber awardURI="info:eu-repo/grantAgreement/EC/H2020/734796/">734796</awardNumber>
      <awardTitle>Research, Demonstration, and Commercialisation of DC Microgrid Technologies</awardTitle>
    </fundingReference>
  </fundingReferences>
</resource>
59
103
views
downloads
All versions This version
Views 5959
Downloads 103103
Data volume 116.1 MB116.1 MB
Unique views 5252
Unique downloads 101101

Share

Cite as