Preprint Open Access

A comprehensive protocol for chemical analysis of flame combustion emissions by secondary ion mass spectrometry

Irimiea Cornelia; Faccinetto Alessandro; Carpentier Yvain; Ortega Ismail-Kenneth; Nuns Nicolas; Therssen Eric; Desgroux Pascale; Focsa Cristian


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://zenodo.org/record/3458058</identifier>
  <creators>
    <creator>
      <creatorName>Irimiea Cornelia</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6193-0426</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8522 - PC2A - Laboratoire de Physico-Chimie des Processus de Combustion et de l'Atmosphère, F-59000 Lille, France, Univ. Lille; CNRS, UMR 8523 - PhLAM - Laboratoire de Physique des Lasers, Atomes et Molécules, F-59000 Lille, France.</affiliation>
    </creator>
    <creator>
      <creatorName>Faccinetto Alessandro</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-8791-0941</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8522 - PC2A - Laboratoire de Physico-Chimie des Processus de Combustion et de l'Atmosphère, F-59000 Lille, France</affiliation>
    </creator>
    <creator>
      <creatorName>Carpentier Yvain</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-1677-4874</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8523 - PhLAM - Laboratoire de Physique des Lasers, Atomes et Molécules, F-59000 Lille, France.</affiliation>
    </creator>
    <creator>
      <creatorName>Ortega Ismail-Kenneth</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-9299-2013</nameIdentifier>
      <affiliation>ONERA – The French Aerospace Laboratory, F-91123 Palaiseau, France</affiliation>
    </creator>
    <creator>
      <creatorName>Nuns Nicolas</creatorName>
      <affiliation>Univ. Lille, CNRS, UMR 2638, Institut M. E. Chevreul, F-59000 Lille, France</affiliation>
    </creator>
    <creator>
      <creatorName>Therssen Eric</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0001-6067-0338</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8522 - PC2A - Laboratoire de Physico-Chimie des Processus de Combustion et de l'Atmosphère, F-59000 Lille, France</affiliation>
    </creator>
    <creator>
      <creatorName>Desgroux Pascale</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-8107-8306</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8522 - PC2A - Laboratoire de Physico-Chimie des Processus de Combustion et de l'Atmosphère, F-59000 Lille, France</affiliation>
    </creator>
    <creator>
      <creatorName>Focsa Cristian</creatorName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-4512-1098</nameIdentifier>
      <affiliation>Univ. Lille, CNRS, UMR 8523 - PhLAM - Laboratoire de Physique des Lasers, Atomes et Molécules, F-59000 Lille, France.</affiliation>
    </creator>
  </creators>
  <titles>
    <title>A comprehensive protocol for chemical analysis of flame combustion emissions by secondary ion mass spectrometry</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2018</publicationYear>
  <subjects>
    <subject>ToF-SIMS</subject>
    <subject>soot</subject>
    <subject>sampling protocol</subject>
    <subject>mass defect</subject>
    <subject>data reduction.</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2018-03-30</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Preprint</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/3458058</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1002/rcm.8133</relatedIdentifier>
  </relatedIdentifiers>
  <version>pre-print</version>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;&lt;strong&gt;RATIONALE.&lt;/strong&gt; Time of flight secondary ion mass spectrometry (ToF-SIMS) is used to provide detailed information on the surface chemical composition of soot. An analytical protocol is proposed and tested on a laboratory flame, and the results are compared with our previous measurements provided by two-step laser mass spectrometry (L2MS).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;METHODS.&lt;/strong&gt; This work details: (1) the development of a dedicated apparatus to sample combustion products from atmospheric flames and deposit them on substrates suitable for ToF-SIMS analysis; (2) the choice of the deposition substrate and the material of the sampling line, and their effect on the mass spectra; (3) a method to separate the contributions of soot and condensable gas based on impact deposition, and finally (4) the post-acquisition data processing.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;RESULTS.&lt;/strong&gt; Compounds produced during flame combustion are detected on the surface of different deposition substrates and attributed a molecular formula based on mass defect&amp;nbsp;analysis. Silicon and titanium wafers perform similarly, while the surface roughness of glass microfiber filters results in a reduced mass resolution. The mass spectra obtained from the analysis of different locations of the deposits obtained by impaction show characteristic patterns that are attributed to soot/condensable gas.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;CONCLUSIONS.&lt;/strong&gt; A working method for the analysis of soot samples and the extraction of useful data from mass spectra is proposed. This protocol should help avoiding common experimental issues like sample contamination, while optimizing the setup performance by maximizing the achievable mass resolution.&lt;/p&gt;</description>
  </descriptions>
  <fundingReferences>
    <fundingReference>
      <funderName>European Commission</funderName>
      <funderIdentifier funderIdentifierType="Crossref Funder ID">10.13039/501100000780</funderIdentifier>
      <awardNumber awardURI="info:eu-repo/grantAgreement/EC/H2020/724145/">724145</awardNumber>
      <awardTitle>Portable Nano-Particle Emission Measurement System</awardTitle>
    </fundingReference>
  </fundingReferences>
</resource>
55
66
views
downloads
Views 55
Downloads 66
Data volume 287.9 MB
Unique views 49
Unique downloads 62

Share

Cite as